18
and the sensor should be replaced see
(Page 19)
.
7>. If the LED displays
“
E8
”
indicates a refrigeration compartment sensor short circuit fault and
the sensor should be replaced see
(Page 19).
8>. If the LED displays
37
℃
, this default only happen in the old model. Bescause the old machine use
the old PCB board. If the sensor is brocken, and the temperature will be infinity; as the PCB board is set
maximum 99, and when the temperature exceed Fahrenheit 99(37
℃
). The solution is to find out the
default sensor and replace it with the same model
’
s
(Fig.18)
○
How to replace sensors
1>. Evaporator sensor (there are two different position a and b of the evaporator sensor)
a.
One is that the evaporator sensor is plugged into the fin of evaporator. Remove the air duct board to
access the sensor plug (A) and unplug in the direction of the arrowhead. See
(Fig.28)
,
then unplug
the other end of sensor from the X11 socket of the control panel, and replace it. See
(Fig.7).
b.
Fig.28
b . The other is that the evaporator sensor is fixed on right side under the evaporator,
Remove the air duct board
to access the sensor,then remove the sensor in the direction of the arrowwhead.replace it.See
(Fig.28.1)
Fig.28.1
2 >
.
Freezing
compartment sensor.
According to the different model, sensor is in the two different position. As the diagram
(Fig.29)
shows below A, A1.