I
nstallation
The tumble dryer is fully compatible with any 600mm deep kitchen units and complies with
stringent EEC regulations.
Your dryer is provided with a vent hose which will extend to approx 2.4m (8ft). We strongly
recommend that this is vented through the wall with the attachment provided. The position of
the hole (100mm diameter) for the vent directly behind the tumble dryer is shown in the
diagram.
If the through the wall vent is to be positioned
anywhere
other than behind the dryer, the vent
hose should be positioned at floor level and through adjacent side panel to a relevant position.
The plinth must be cut
out to accommodate the air vent grill at the bottom front of the tumble
dryer
(see the dimensions below)
.
IMPORTANT
The air vent at the front of the appliance must never be covered or blocked in any way as this
will cause the dryer to overheat.
This appliance must not be installed behind a lockable door, a sliding door or a door with
hinges on the opposite side to that of the tumble dryer.
The dryer should not be placed directly next to ovens or cookers, as the performance of the
dryer may be affected.
Electrical connections
: We strongly recommend that any electrical work is carried out by a
qualified person complying with the IEE 17
th
addition of the electrical regulations.