Instruction manual C871GBK
Please keep this instruction manual for future reference
17
CONNECTION TO FLEXIBLE STEEL TUBE
The gas feed connector to the appliance is a threaded, male 1/2” connector for round gas pipe.
Only use pipes and sealing gaskets that conforms to the standards currently in force. The maximum
length of the flexible pipes must not exceed 2000 mm. Once the connection has been made,
ensure that the flexible metal tube does not touch any moving parts and is not crushed.
CHECK THE INSTALLATION
Once the appliance has been installed, make sure all the connections are properly sealed, using
liquid detector fluid and a ‘U’ gauge. Never use a flame.
ELECTRICAL CONNECTION
(The hob is fitted with a standard 13A plug)
Fit the supply cable with a standard plug for the demand rate indicated on the rating plate or
connect it directly to the electrical mains. In the latter case, a single pole switch must be placed
between the appliance and the mains, with a minimum opening between the contacts of 3 mm in
compliance with current safety codes (the earth wire must not be interrupted by the switch). The
power supply cable must be positioned so that it does not reach a temperature in excess of 50~C
above room temperature at any point.
BEFORE ACTUAL CONNECTION MAKE SURE THAT:
-
The fuse and electrical system can withstand the load required by the appliance;
-
That the electrical supply system is equipped with an efficient earth hook-up according to the
norms and regulations prescribed by law;
-
That the plug or switch are easily accessible.
Important:
The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow
Earth
Blue
Neutral
Brown
Live
C871GBK - Instruction Manual.indd 17