W I R I N G A N D S A F E T Y
The instructions given below MUST be adhered to during wiring:
› This appliance is designed to connect to 220-240V~ and is rated at 32Amps and as such
needs to be hard wired to the electrical supply.
› If the electrical supply is different from the value given above, call Caple
Service immediately.
› Wiring of the appliance must be performed by a qualified installer/electrician.
› The earth cable must be connected via the terminal screw with the earthing mark. Supply
cable connection must be as shown in the diagram. If there is no earthed outlet conforming
to regulations in the installation environment, the installation cannot go ahead and an
Electrician should be consulted immediately.
› The installation must include a suitable isolating switch with a minimum contact opening of
3mm between the appliance and the mains. The isolating switch should be sized according
to the load on the rating plate “32Amp”and should comply with
current regulations.
› The earthed outlet must be in close vicinity of the appliance. Never use an extension lead.
› The supply cable should not make contact with the product’s hot surface.
› In case of any damage to the supply cable, please call Caple Service. The cable must be
replaced by a qualified installer/electrician)
› Faulty wiring may damage the appliance. Such damage will not be covered by the warranty.
› When wiring the terminal box care should be taken to fit and tighten the links on the live