15
Instruction manual C2105SS
14
Please keep this instruction manual for future reference
Instruction manual C2105SS
Please keep this instruction manual for future reference
C O N T R O L PA N E L A N D D I S P L AY
1
Control Panel and display
Button Description
1
○
Power
2
○
Programme
○
3 Timer
4
○
Temperature
5
○
Light
6
○
Up / Down (+/-)
○
7
Select
8
○
Boost
○
9 S tart
/ Pause
Display Description
10
○
Function
/ programme
11
○
Time
r
12
○
Actual Temperature/Time
13
○
Set Temperature
14
○
Curr ent Time
15
○
Safety Lock
6
1
○
Boost
7
1
○
Cooking Dura tion Time
8
1
○
Rotisserie
9
1
○
Alarm
0
2
○
Heating Indicator
1
2
○
Light
2
2
○
Cooking End Time
1
2
4
3
10
11
13
12
16
14
15
6
5
19
17
18
21
20
22
7
8
9
B U T TO N
D E S C R I P T I O N
1. Power
2. Programme
3. Timer
4. emperature
5. Light
6. Up / Down (+/-)
7. Select
8. Boost
9. Start / Pause
D I S P L AY
D E S C R I P T I O N
10. Function / programme
11. Timer
12. Actual Temperature/Time
13. Set Temperature
14. Current Time
15. Safety Lock
16. Boost
17. Cooking Duration Time
18. Rotisserie
19. Alarm
20. Heating Indicator
21. Light
22. Cooking End Time
E L E C T R I C A L C O N N E C T I O N
WA R N I N G : T H I S A P P L I A N C E M U S T B E E A RT H E D
Check that the power rating of the mains supply is suitable for the maximum power of the
appliance as indicated on the rating label.
The fuse rating for this appliance is 16amp.
The appliance is supplied with a mains lead it should be “Hard wired” as follows:
»
The “yellow/green” earth wire, which must be connected to a terminal, and has to be about
10mm longer than the other wire.
»
The neutral wire has to be connected to the terminal marked with a letter N.
»
The Live wire should only be connected to the terminal marked L.
Mains connection can also be made by fitting a double pole switch with a minimum gap between
the contacts of 3mm, proportionate to the load and complying with the regulations in force.
THE YELLOW/GREEN EARTH WIRE SHOULD NOT BE CONTROLLED BY THE SWITCH.
When a double pole switch is used for mains supply connection it should be easily accessed, once
the appliance is in position.
I M P O RTA N T:
The mains supply cable should be positioned so that it is never subjected to temperatures which
are more than 50ºC above ambient temperature.
The electrical safety of the appliance can only be guaranteed when it has been correctly
connected to a properly earthed mains electrical supply, as laid down in the current regulations for
electrical safety.
The manufacturer cannot be held responsible for any damage to persons or objects due to lack of
an earth connection.
The ovens are designed to operate with a mono-phase alternating current of
220-240V, 50Hz.
BEFORE THE INSTALLATION OF THE APPLIANCE, CHECK THE SPECIFICATIONS ON THE
RATING LABEL.
2 x Chrome oven shelves
1 x Grill pan with rack and handle
2 x Telescopic runners (x2 pairs)
1 x Rotisserie
To purchase additional or replacement accessories, please visit www.caple.co.uk
A C C E S S O R I E S