SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a
GAS SAFE registered installer.
This is a condition of the Gallery guarantee
schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney.
The pilot assembly must be changed on an annual basis as a
condition of the guarantee.
The condition of the coals should be checked and
if
necessary the whole set should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access.
After any servicing work a gas tightness check must always be
carried out.
For Diagrams refer to Section 2
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the front bars / ashpan cover put them in a safe location.
Remove the loose coals from the fuel bed. Remove the fuelbed matrix.
4.1.3
Isolate the gas supply and remove the inlet pipe from the appliance
inlet elbow. Unscrew and remove the two screws which retain the
burner at the base. Lift the burner retaining tabs from the rear of the
firebox & remove the burner assembly from the fire.
4.1.4
To refit the burner assembly. Push the retaining tabs into the rear panel
of the firebox and secure the burner at the base of the control panel
with two screws. Refit the gas supply pipe and carry out a gas
tightness test. Refit the coals referring to section 3 for the correct layout.
The ashpan and front bars can now be re-positioned.
4.2
Removing the Piezo Igniter
4.2.1
Remove the burner assembly as in section 4.1
4.2.2
Disconnect the ignition lead from the piezo and unscrew the
retaining nut on the rear of the control panel. Withdraw the piezo from
the front of the control panel. Re-assemble in reverse order and carry
out a gas tightness test.
26