8.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R30

. In case the 

device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 3 - Commands table

).

 

9.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R30

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head for the environment to be monitored. On the way, to check the quality of the radio coverage, use the "

Field Measurer

" function. 

This function is activated issuing the 

TEST

 (

refer t

Picture 3 - Commands table

)command: position th

WineCapKey

 in the spot indicated 

in 

Picture  2  -  WineCapKey  positioning

  and  wait  for  two 

AMBER

  flashes,  then  remove  the 

WineCapKey

  from  device.  The  "

Field 

Measurer

" function lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 second cadence.  

For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse and 

activate the "

Field

 

Measurer

" function.

 

 

The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long

 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long

 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12 repeater

 should be put between (

refer to 

WineCap System - User Manual 

R30

). Th

WR12 repeater

 

itself must be in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with th

WR12 repeater

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force the 
operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R30

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

 

 

Picture 4 - Status table - Radio signal quality

 

Summary of Contents for WineCap WSD15IIDIST

Page 1: ...urement time For the average to be carried out correctly the Follower function on the pitch and roll channel active by default must be enabled Otherwise the average will be performed with the cadence of the Measurement time The setting of these times is configurable and modifiable through the WineCapManager software or through the cloud b Measure thresholds Two thresholds can be set for each slope...

Page 2: ...nded for dynamic event displays By sudden event is meant as significant displacement related to the position of rest in which the instrument is working d Reset installation position After installation and fixing a 6 1 command can be issued see Picture 3 Commands table which resets the channels dedicated to the inclination The command starts a first acquisition which determines the absolute positio...

Page 3: ...r pointer There is a laser aiming function by giving the command 7 see Picture 3 Commands table the laser is activated and allows a precise aim at the target This function ceases when a measurement is performed by the datalogger or if command 7 is given again It is recommended to use a white non glossy and possibly smooth material as a target 4 Thermometer operating logic The value reported on cha...

Page 4: ...dify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 mode and automatically the device s clock is aligned with the PC s clock to assure the temporal reference of the sample Sampling operations start may be selected disconnecting the USB cable or giving the proper command with the magnetic key refer to 10 Stand alone USB datalogger installatio...

Page 5: ...TANDBY status refer to WIRELESS MODE STATUS Table 5 flashes 5 flashes FACTORY RESET The device performs the memory deleting procedure and goes in STOP status All samples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to conf...

Page 6: ...ifferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Ra...

Page 7: ...unt Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 11 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 3 Commands table It corresponds to th...

Page 8: ...Three axis accelerometer Inclination Measure range 6 5000 6 5000 Inclination Measure accuracy 0 5 of measure Inclination Measure resolution 0 0002 Temperature Transducer type NTC10KΩ Temperature Measure range 30 C 60 C Temperature Measure accuracy 0 5 C Range 30 C 0 C 0 2 C Range 0 C 60 C Temperature Measure resolution 0 01 C Relative distance Transducer type LASER distance meter Relative distance...

Page 9: ...o cause unwanted behaviour Modifications or tampering not expressly approved by the Manufacturer could void the user s authorization to operate the equipment This equipment must be installed by qualified personnel This equipment contains a Class 2 laser The user should avoid pointing the laser directly into the eye while the device is powered The device has a weight of up to 1 6 kg Make sure that ...

Page 10: ...2011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point...

Reviews: