By appropriately adjusting the “

Delta

” values, it is therefore possible to manage movements and react to sudden events without 

waiting for the times introduced by the average.  

The device does 

NOT

 respond to 

SHOCK

 events and cannot be intended for dynamic event displays. By "sudden event" is meant as 

significant displacement related to the position of rest in which the instrument is working. 

d.

 

Reset installation position. 

After installation and fixing, a "6 + 1" command can be issued (see 

Picture 3 - Commands table

), which resets the channels dedicated 

to the inclination. 

The command starts a first acquisition which determines the absolute position of the tool and the consequent rotation of the axes 
to align the internal references. At the end of the procedure, the zero value and the position of the axes are saved in the memory 
so that they can be recovered in case of restart of the device. 

 

This procedure takes about 5 minutes. 

 

  

 

Summary of Contents for WineCap WSD15IIDIST

Page 1: ...urement time For the average to be carried out correctly the Follower function on the pitch and roll channel active by default must be enabled Otherwise the average will be performed with the cadence of the Measurement time The setting of these times is configurable and modifiable through the WineCapManager software or through the cloud b Measure thresholds Two thresholds can be set for each slope...

Page 2: ...nded for dynamic event displays By sudden event is meant as significant displacement related to the position of rest in which the instrument is working d Reset installation position After installation and fixing a 6 1 command can be issued see Picture 3 Commands table which resets the channels dedicated to the inclination The command starts a first acquisition which determines the absolute positio...

Page 3: ...r pointer There is a laser aiming function by giving the command 7 see Picture 3 Commands table the laser is activated and allows a precise aim at the target This function ceases when a measurement is performed by the datalogger or if command 7 is given again It is recommended to use a white non glossy and possibly smooth material as a target 4 Thermometer operating logic The value reported on cha...

Page 4: ...dify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 mode and automatically the device s clock is aligned with the PC s clock to assure the temporal reference of the sample Sampling operations start may be selected disconnecting the USB cable or giving the proper command with the magnetic key refer to 10 Stand alone USB datalogger installatio...

Page 5: ...TANDBY status refer to WIRELESS MODE STATUS Table 5 flashes 5 flashes FACTORY RESET The device performs the memory deleting procedure and goes in STOP status All samples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to conf...

Page 6: ...ifferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Ra...

Page 7: ...unt Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 11 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 3 Commands table It corresponds to th...

Page 8: ...Three axis accelerometer Inclination Measure range 6 5000 6 5000 Inclination Measure accuracy 0 5 of measure Inclination Measure resolution 0 0002 Temperature Transducer type NTC10KΩ Temperature Measure range 30 C 60 C Temperature Measure accuracy 0 5 C Range 30 C 0 C 0 2 C Range 0 C 60 C Temperature Measure resolution 0 01 C Relative distance Transducer type LASER distance meter Relative distance...

Page 9: ...o cause unwanted behaviour Modifications or tampering not expressly approved by the Manufacturer could void the user s authorization to operate the equipment This equipment must be installed by qualified personnel This equipment contains a Class 2 laser The user should avoid pointing the laser directly into the eye while the device is powered The device has a weight of up to 1 6 kg Make sure that ...

Page 10: ...2011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point...

Reviews: