MODEL NO. 088-0733-8
8
10
L
IG
H
T
IN
G
LEAK TEST
1. Make sure the control knob is on the “ ” position.
2. Make sure the gas cylinder is correctly and se curely connected to the pressure regulator, without
over-tightening it.
3. Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and
connections between the control knob and gas cylinder.
4. If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the
leaking connection, reconnect it and try aga in. If the leak persists, consult the customer service
centre for assistance.
5. If the connection is sound, continue to the next step.
1. Make sure control valve is “ ”.
2. Turn on gas tank valve.
3. Press in and turn control valve knob counterclockwise
to the left “ ” to ignite. See the figure to the right.
4. If burner is lit, do not stop pressing in the control valve knob for
a minute to heat the thermocouple.
5. When control valve knob is released, the burner should be lit.
after completing Step 3 before attempting to reignite.
6. Press in and turn control valve knob to desired heat setting: left “ ” is high;
!!!WARNING!!!
Do not use an open flame to check for leaks.
Do not smoke during testing.
Do not test indoors.
A leak check must be performed whenever the gas cylinder is replaced.
If not, turn control valve knob clockwise to “ ”. Wait 5 minutes
down “ ” is low.
G
A
S
C
O
N
N
E
C
T
IO
N
L
E
A
K
C
H
E
C
K
OPERATION
Fig. 8
Fig. 9