FFor optimum performance we recommend a minimum distance of 10 cm between the unit and the
ceiling.
Refer to the following diagram to ensure proper distance from walls and ceiling:
NOTE FOR CONCRETE OR BRICK WALLS:
2.3m (90.55in) or more
fig 3.1
fig 3.2
At least 7 cm
Wall
Indoor
Outdoor
7 - 5 mm
(0
.2
-0
.3in
)
12cm (4.75in)
or more
12cm (4.75in)
or more
The mounting plate is the device on which you will
mount the indoor unit.
You must drill a hole in the wall for refrigerant piping, the
drainage pipe, and the signal cable that will connect the
indoor and outdoor units.
If the wall is made of brick, concrete, or similar material, drill
5mm-diameter (0.2in-diameter) holes in the wall and insert the
sleeve anchors provided. Then secure the mounting plate to
the wall by tightening the screws directly into the clip anchors.
When drilling the wall hole, make sure to avoid wires,
plumbing, and other sensitive components.
1.
Remove the screw that attaches the mounting plate to
the back of the indoor unit.
2. Place the mounting plate against the wall in a location
that meets the standards in the Select Installation
Location step. (See Mounting Plate Dimensions for
detailed information on mounting plate sizes.)
3. Drill holes for mounting screws in places that:
• have studs and can support the weight of the unit
• correspond to screw holes in the mounting plate
4. Secure the mounting plate to the wall with the screws
provided.
5. Make sure that mounting plate is flat against the wall.
1.
1. Determine the location of the wall hole based on
the position of the mounting plate. Refer to Mount-
ing Plate Dimensions on the next page to help you
determine the optimal position. The wall hole should
have a 65mm (2.5in) diameter at least, and at a
slightly lower angle to facilitate drainage.
2. Using a 65mm (2.5in) or 90mm(3.54in) (depending
on models )core drill, drill a hole in the wall. Make
sure that the hole is drilled at a slight downward an-
gle, so that the outdoor end of the hole is lower than
the indoor end by about 5mm to 7mm (0.2-0.275in).
This will ensure proper water drainage. (See Fig. 3.2)
3. Place the protective wall cuff in the hole. This pro-
tects the edges of the hole and will help seal it when
you finish the installation process.
STEP 2: ATTACH MOUNTING PLATE TO WALL
STEP 3: DRILL WALL HOLE FOR
CONNECTIVE PIPING
CAUTION
INDOOR UNIT INSTALLATION
46
© 2021, Elon Group AB. All rights reserved.
EN