Post out/out dimension
① :
In case of
D18 + D18 D=3635mm
② :
In case of
D21 + D21 D=4235mm
③ :
In case of
D24 + D24 D=4835mm
④ :
In case of
D25 + D25 D=5115mm
⑤ :
In case of
D27 + D27 D=5435mm
⑥ :
In case of
D30 + D30 D=6035mm
⑦ :
In case of
D33 + D33 D=6635mm
a :
In case of
D18 + D21 D=3935mm
b :
In case of
D18 + D24 D=4235mm
c :
In case of
D18 + D25 D=4375mm
d :
In case of
D18 + D27 D=4535mm
e :
In case of
D18 + D30 D=4835mm
f :
In case of
D18 + D33 D=5135mm
g :
In case of
D21 + D24 D=4535mm
h :
In case of
D21 + D25 D=4675mm
i :
In case of
D21 + D27 D=4835mm
j :
In case of
D21 + D30 D=5135mm
k :
In case of
D21 + D33 D=5435mm
l :
In case of
D24 + D25 D=4975mm
m :
In case of
D24 + D27 D=5135mm
n :
In case of
D24 + D30 D=5435mm
o :
In case of
D24 + D33 D=5735mm
p :
In case of
D25 + D27 D=5275mm
q :
In case of
D25 + D30 D=5575mm
r :
In case of
D25 + D33 D=5875mm
s :
In case of
D27 + D30 D=5735mm
t :
In case of
D27 + D33 D=6035mm
u :
In case of
D30 + D33 D=6335mm
Please implant the post as below in order to
adjust the top end of the roof.
In case of a, implant the post for D21 42.9mm deeper than the post for D18.
In case of b, implant the post for D24 79.4mm deeper than the post for D18.
In case of c, implant the post for D25 95.2mm deeper than the post for D18.
In case of d, implant the post for D27 111.8mm deeper than the post for D18.
In case of e, implant the post for D30 138.9mm deeper than the post for D18.
In case of f, implant the post for D33 175.1mm deeper than the post for D18.
In case of g, implant the post for D24 36.5mm deeper than the post for D21.
In case of h, implant the post for D25 52.2mm deeper than the post for D21.
In case of i, implant the post for D27 68.9mm deeper than the post for D21.
In case of j, implant the post for D30 95.9mm deeper than the post for D21.
In case of k, implant the post for D33 132.2mm deeper than the post for D21.
In case of l, implant the post for D25 15.8mm deeper than the post for D24.
In case of m, implant the post for D27 32.4mm deeper than the post for D24.
In case of n, implant the post for D30 59.5mm deeper than the post for D24.
In case of o, implant the post for D33 95.7mm deeper than the post for D24.
In case of p, implant the post for D27 16.6mm deeper than the post for D25.
In case of q, implant the post for D30 43.7mm deeper than the post for D25.
In case of r, implant the post for D33 79.9mm deeper than the post for D25.
In case of s, implant the post for D30 27.1mm deeper than the post for D27.
In case of t, implant the post for D33 63.3mm deeper than the post for D27.
In case of u, implant the post for D33 36.2mm deeper than the post for D30.
1
Installation of connecting material
Installation procedure
After installing the roof as below figure, install the connecting material on the front frame.
※
Before installing the roof panels, install the connecting material.
G.L
D1
D=D1+D2+35
D2
35
4