Connecting the Camera
Internal Connection Diagram
■
External Device Input Terminals
The external device input terminal consists of a positive terminal (IN) and negative terminal
(GND). Connecting cables to the positive and negative terminals and opening or closing
the circuit notifies the Viewer.
Important
• When connecting sensors and switches, use those that have terminals which are
isolated from internal power and GND.
■
External Device Output Terminals
The external device output terminal consists of an OUT terminal and a GND terminal.
Controls from the viewer can be used to open and close the circuit between the terminals.
A MOSFET device is used for the output terminal.
Rating range for load connected to output terminals
Rating between terminals
Maximum voltage 50 V DC
Continuous load current at or below 100 mA
On resistance: Below 1 Ω
In
ter
nal c
on
tr
oller
IN
Input terminal
GND
GND
OUT
Output terminal
10kΩ
10kΩ
0.1μF
1kΩ