![background image](http://html1.mh-extra.com/html/canon/realis-sx80-mark-ii-d/realis-sx80-mark-ii-d_supplementary-manual_4078867005.webp)
8. Sharpness
8.1 [Set Sharpness] Commands
Commands for setting the sharpness, or for acquiring the sharpness setting value.
PC
⇒
PRJ
Setting value
SHARP=<number><CR>
53h 48h 41h 52h 50h 3Dh <character code> 0Dh
GET SHARP<CR>
47h 45h 54h 20h 53h 48h 41h 52h 50h 0Dh
Example:
SHARP=-4<CR>
53h 48h 41h 52h 50h 3Dh 2Dh 34h 0Dh
8.2 [Set Sharpness] Responses
Responses to commands for setting the sharpness, or for acquiring the sharpness setting value.
PRJ
⇒
PC
Success
i:OK<CR>
69h 3Ah 4Fh 4Bh 0Dh
Failure
<Refer to the Error List>
g:SHARP=<number><CR>
67h 3Ah 53h 48h 41h 52h 50h 3Dh <character code> 0Dh
Example:
g:SHARP=-2<CR>
67h 3Ah 53h 48h 41h 52h 50h 3Dh 2Dh 32h 0Dh
9. Contrast
9.1 [Set Contrast] Commands
Commands for setting the contrast, or for acquiring the contrast setting value.
PC
⇒
PRJ
Setting value
CONT=<number><CR>
43h 4Fh 4Eh 54h 3Dh <character code> 0Dh
GET CONT<CR>
47h 45h 54h 20h 43h 4Fh 4Eh 54h 0Dh
Example:
CONT=-4<CR>
43h 4Fh 4Eh 54h 3Dh 2Dh 34h 0Dh
9.2 [Set Contrast] Responses
Responses to commands for setting the contrast, or for acquiring the contrast setting value.
PRJ
⇒
PC
Success
i:OK<CR>
69h 3Ah 4Fh 4Bh 0Dh
Failure
<Refer to the Error List>
g:CONT=<number><CR>
67h 3Ah 43h 4Fh 4Eh 54h 3Dh <character code> 0Dh
Example:
g:CONT=-2<CR>
67h 3Ah 43h 4Fh 4Eh 54h 3Dh 2Dh 32h 0Dh
ASCII Notation
Binary Notation
Contrast
Get contrast
Sharpness
Get sharpness
Command Type
Get contrast
Response Type
ASCII Notation
Binary Notation
Contrast
Command Type
ASCII Notation
Binary Notation
Sharpness
Get sharpness
Response Type
ASCII Notation
Binary Notation