CHAPTER 4 SERVICE MODE
4-3
Figure 4-4
30
31
32
33
34
35
36
37
38
REGIST
LE_BLANK
PRIMARY
IP_OFST
PW_OFST
IP_ADJ
LENS_ADJ
PREX_LP
LAMP_ADJ
FB5-2777
4.
Clearing the Error Code from Memory
If 'E000', 'E001', 'E002', or 'E003' is indicated, remove the cause of the error, and clear the
memory.
1) Turn on the power while shorting JP103 and JP104 on the DC controller PCB with a screw-
driver.
• The display will indicate 'F'.
Figure 4-3
2) Turn off and then on the power switch to check the copying operation.
SERVICE
JP104
JP104
JP103
Caution:
When a fault associated with 'E000', 'E001', 'E002', or 'E003' is detected, the power will auto-
matically turn off. It will still turn off even when turned on without removing the fault.
To find out which code turned off the power, disconnect J207 from the composite power
supply PCB, and turn on the power.
Figure 4-4 shows the label attached behind the front upper cover. At the factory, each indi-
vidual machine is adjusted, and its adjustment values are recorded on the label.
If you have entered any new value in the field, be sure to record it on the label. If you have
replaced the DC controller PCB, be sure to enter the values recorded on the label in service
mode.
If you have replaced the drum unit, composite power supply PCB, or pre-exposure PCB, on
the other hand, be sure to enter the values recorded on the label of the appropriate part. Then,
record these values on the service label.
Summary of Contents for NP6412
Page 6: ......
Page 12: ......
Page 34: ......
Page 46: ......
Page 48: ......
Page 92: ......
Page 144: ......
Page 176: ......
Page 178: ......
Page 192: ......
Page 194: ......
Page 220: ......
Page 222: ......
Page 256: ......
Page 258: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 384: ......
Page 388: ......
Page 414: ......
Page 424: ......
Page 430: ......
Page 432: ......
Page 434: ......
Page 484: ......
Page 492: ......
Page 502: ......
Page 506: ......
Page 516: ......
Page 599: ...PRINTED IN JAPAN IMPRIME AU JAPON ...