2-38
CHAPTER 2 STANDARDS AND ADJUSTMENTS
b. Multifeeder
1) Start [4] in service mode, and select No. 412 using the keypad.
•
The indicator indicates ‘412’.
2) Press the OK key.
•
The indicator indicates ‘A6’.
3) Set the manual guide plate of the multifeeder to A6R (105 mm).
Figure 2-53
4) Press the OK key.
•
The indicator indicates ‘A4r’.
5) Set the manual guide plate to A4R (210 mm).
6) Press the OK key.
•
The indicator indicates ‘A4’.
7) Set the manual guide plate to A4 (297 mm).
8) Press the OK key.
•
The indicator indicates ‘A6’.
9) Press the Reset key twice to end service mode.
Guide
Guide
Paper