SERIAL FUNCTIONAL SPECIFICATION                                                                                      Page 6 of 18 

 
7.  Functional Execution Command 

7.1.  Format 

1)    PC issues a command as below form at 

“C”                                      [CR] 

Command: 2 characters (See Functional Execution Command Table) 

COMMAND 

2)  A projector decodes received data and sends a return result after being ready to receive 

next command. 

[ACK] [CR]:

0x06,0x0D

When received functional execution commands. 

“?” [CR]: When cannot read received data

 

7.2.    When the command pipelining is needed 

When some functions need command pipelining , the performance is the same as the remote 

control’s performance. 

1)    System: issue any commands every 100ms after receiving response 

2)    When receiving the same command continuously with 120ms, the function is executed 

for 120ms from that moment. 

3)    When receiving the same command continuously, with 120ms, the function is executed 

for 120ms form the moment. 

4)    The next command is not issued after 120ms, and the execution is stopped. 

5)  If the projector receives other incoming commands within 120ms, the execution is 

stopped. 

7.3.  Transfer Example 

Change to Video mode with Basic Command 

 

 

 

 

 

   

 Command 

PC 

!

 Projector  

 “C”   ”0”  ”7”  CR 

Projector 

!

 PC  

 

 

 

                    ACK    CR 

 

 

 

 

 

 

              Processing 

 

 

 

 

 

 

      (A few ms--1s) 

7.4.  Operation Requirements 

When the projector’s status in this below, functional execution commands are limited. 

Status Read Commands are available even in this table status.

 

Projector Status 

Available Functional Execution Commands 

StandBy Mode 

C00: Power ON 

Processing Countdown 

C00: Power ON (Terminate Countdown) 
C01: Power OFF 

Processing Cooling Down 

N/A 

Processing Cooling Down due to abnormal 

 temperature. 

N/A 

Abnormal Temperature Status 

N/A 

Processing Power Save / Cooling Down 

N/A 

Processing Power Save 

C00: Power ON, C01: Power OFF 

Note) When the status is above, even if the projector receives other command in the above 

status, the projector returns [ACK] [CR]. 

 

 

Summary of Contents for LV-S4

Page 1: ...LV S4 SERIAL FUNCTIONAL SPECIFICATION History of Modification Rev Contents Date Note New Document 2005 03 01...

Page 2: ...o Command 7 7 10 Volume Command 7 7 11 Volume Command 8 7 12 Audio Mute ON Command 8 7 13 Audio Mute OFF Command 8 7 14 Video Mute ON Command 8 7 15 Video Mute OFF Command 8 7 16 Screen Normal size Co...

Page 3: ...12 7 41 Pointer Down Command 12 7 42 Enter Command 13 7 43 Freeze ON Command 13 7 44 Freeze OFF Command 13 7 45 Computer Analog RGB Command 13 7 46 Computer Scart Command 13 7 47 Computer Component C...

Page 4: ...Shynchro system Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity None Stop Bit 1 Flow Control None 1 Transfer rate initial setting value is 19200 2 Transfer rate can be changed by s...

Page 5: ...l initialization after plugging in AC During this time it cannot process command Do not issue any commands 4 9 7 seconds after StandBy or Power ON even when a projector receives a command a computer r...

Page 6: ...ute ON C3A Pointer Right C0E Video Mute OFF C3B Pointer Left C0F Screen Normal size 4 3 C3C Pointer Up C10 Screen Wide size 16 9 C3D Pointer Down C11 Image Standard C3F Enter OK C12 Image High contras...

Page 7: ...ion is executed for 120ms form the moment 4 The next command is not issued after 120ms and the execution is stopped 5 If the projector receives other incoming commands within 120ms the execution is st...

Page 8: ...ecuted Acceptable ACK CR Response Unacceptable CR 7 7 Power OFF Command Command C02 CR Detail Power OFF Stand By When Power OFF with POWER button of the projector or the remote control Power OFF will...

Page 9: ...d works same as MUTE of the Remote Control button but this command does not work for MUTE ON Acceptable ACK CR Response Unacceptable CR 7 14 Video Mute ON Command Command C0D CR Detail Video Mute ON T...

Page 10: ...age to High contrast mode Acceptable ACK CR Response Unacceptable CR 7 20 Image Cinema Command Command C13 CR Detail Set Image to Cinema mode Acceptable ACK CR Response Unacceptable CR 7 21 Image Cust...

Page 11: ...0 CR Detail Brightness of user control 1 Acceptable ACK CR Response Unacceptable CR 7 27 Brightness Command Command C21 CR Detail Brightness of user control 1 Acceptable ACK CR Response Unacceptable C...

Page 12: ...d in EEPROM and even if turning OFF and ON Acceptable ACK CR Response Unacceptable CR 7 33 Power Management Shut Down Command Command C2E CR Detail Set Power Management to Shut down mode This status i...

Page 13: ...as the Remote control s Acceptable ACK CR Response Unacceptable CR 7 39 Pointer Left Command Command C3B CR Detail Move Pointer to left On Screen Display Menu This command works the same as the Remote...

Page 14: ...4 Freeze OFF Command Command C44 CR Detail Return to Freeze OFF screen This command works the same as the Remote control s FREEZE button Do not work the Freeze ON Acceptable ACK CR Response Unacceptab...

Page 15: ...Presentation Timer Command Command C8A CR Detail Set a presentation timer to active This command works the same as the Remote control s P TIMER button Acceptable ACK CR Response Unacceptable CR 7 50...

Page 16: ...Example Get input mode for the projector by basic commands COMMAND current input mode command issue PC Projector C R 1 CR Projector PC 1 CR Response A few ms 1s Shows Computer is selected 8 3 Status R...

Page 17: ...time defers from models This Cooling Down Works for lamps and other optical accessories Control commands are not available for this status 5 10 CR Status Abnormal power supply voltage When the power s...

Page 18: ...ement function is ON in setting menu and there is no signal for 5 minutes it moves on to PowerSave status after PowerSave and Cooling Down Moving on to the status of Power On is the same action as mov...

Page 19: ...3 1 Temperature sensor 1 2 Temperature sensor 2 3 Temperature sensor 3 Temperature data form shows as 00 0 When the temperature sinks to the first character is like 05 5 CR When cannot return the tem...

Reviews: