SERIAL FUNCTIONAL SPECIFICATION Page 17 of 18
9) ”24” [CR]
Status: Processing Power Save / Cooling Down
When Power Management function is ON in setting menu and there is no signal for 5
minutes, it moves on to Power Save/Cooling Down after tuning off the lamps. (During
this process, Green LED is OFF.)
The control command is invalid
After this Power Save/Coolign Down continues for about 90 seconds, it moves on to
Power Save.
(
Green LED flashes.
)
Status:
No signal Power Save / Cooling Down Power Save
Response ”00” ”24” ”04
”
After 5 minutes with no signal after about 90 seconds
10) ”04” [CR]
Status of Power Save
When the Power Management function is ON in setting menu, and there is no
signal for 5 minutes, it moves on to PowerSave status after PowerSave and Cooling
Down.
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.
・
Power ON Command:”C00”[CR]
・・・・・・・・
move on the status of power on
・
Power OFF Command:”C01”[CR]
・・・・・
move on the status of stand by
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.
8.4. Input Mode Read Command
Command
“CR1” [CR]
Detail
Get selected Input No.
Acceptable
“%1” [CR]
%1
”1” = Computer is selected
“3” = Video is selected
Response
Unacceptable “?” [CR]
8.5. Lamp Time Read Command
Command
“CR3” [CR]
Detail
Get total lamp running hours.
Acceptable
“%1” [CR]
%1
Show as 4 digits
Ex.: “0410”[CR]
!
410 hours
Response
Unacceptable “?” [CR]