background image

 

SERIAL FUNCTIONAL SPECIFICATION                                                                                      Page 4 of 18 

 
4.  Notes for Communication 

4.1.  The projector command is defined one command/one line that starts “C” and ends carriage 

return (0x0D). 

4.2.    The projector starts decoding after the carriage return. 

4.3.    There are two types of command, functional execution commands and state read commands.     

Example of Functional Execution Command: “C05” [CR] 

Example of State Read Command: “CR0” [CR] 

4.4.    It clears information of accepting buffer as following terms. 

1)    When a projector receives LF

0xoA

 or EOF

0x1A

 

2)  When it takes more than one second to receive on e command. 

(Until the projector receives the carriage return after the projector receives the first 

data.) 

4.5.    When control command pipelining, after the response, wait interval of time as below. 

1)    COMMAND such as ”/-“ 

!

 100ms 

2)  Other COMMAND 

!

 500ms 

4.6.    Wait at least 500 ms after the response, when status read command pipelining. 

4.7.    Do not issue any command before the Response. 

When there is no response after 5 seconds, issue next command. 

4.8.    It takes about 7 seconds for internal initialization after plugging in AC.    During this time, it 

cannot process command.    Do not issue any commands. 

4.9.    7 seconds after StandBy or Power ON, even when a projector receives a command, a computer 

receives acceptable response, but it does not execute for internal initialization and lamp 

lighting process.  However, Status Read Commands are executed after 500ms when they 

receive acceptable response. 

4.10.    About performance during processing count down or cooling down. 

When a projector receives After Stand By or Power ON, Even when a projector receives a 

command, a computer receives response to accept the command, but it does not execute for 

internal initialization and lamp lighting process.  However, Status Read Commands are 

executed. 

4.11.  About performance when changing INPUT. 

After receiving INPUT switching command, when receiving commands between 5 seconds 

from starting the switching to completing the switching, a computer receives acceptable 

command, but it is not executed.   

However, status read commands are executed after a computer receives response to accept 

the command, after 500ms.     

4.12.  Response for Status Read Command after accepting has different characters.  See ”Status 

Read Command Table”. 

4.13.    Characters for commands must be Capital (A - Z).     

 
 
 
 

 

Summary of Contents for LV-S4

Page 1: ...LV S4 SERIAL FUNCTIONAL SPECIFICATION History of Modification Rev Contents Date Note New Document 2005 03 01...

Page 2: ...o Command 7 7 10 Volume Command 7 7 11 Volume Command 8 7 12 Audio Mute ON Command 8 7 13 Audio Mute OFF Command 8 7 14 Video Mute ON Command 8 7 15 Video Mute OFF Command 8 7 16 Screen Normal size Co...

Page 3: ...12 7 41 Pointer Down Command 12 7 42 Enter Command 13 7 43 Freeze ON Command 13 7 44 Freeze OFF Command 13 7 45 Computer Analog RGB Command 13 7 46 Computer Scart Command 13 7 47 Computer Component C...

Page 4: ...Shynchro system Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity None Stop Bit 1 Flow Control None 1 Transfer rate initial setting value is 19200 2 Transfer rate can be changed by s...

Page 5: ...l initialization after plugging in AC During this time it cannot process command Do not issue any commands 4 9 7 seconds after StandBy or Power ON even when a projector receives a command a computer r...

Page 6: ...ute ON C3A Pointer Right C0E Video Mute OFF C3B Pointer Left C0F Screen Normal size 4 3 C3C Pointer Up C10 Screen Wide size 16 9 C3D Pointer Down C11 Image Standard C3F Enter OK C12 Image High contras...

Page 7: ...ion is executed for 120ms form the moment 4 The next command is not issued after 120ms and the execution is stopped 5 If the projector receives other incoming commands within 120ms the execution is st...

Page 8: ...ecuted Acceptable ACK CR Response Unacceptable CR 7 7 Power OFF Command Command C02 CR Detail Power OFF Stand By When Power OFF with POWER button of the projector or the remote control Power OFF will...

Page 9: ...d works same as MUTE of the Remote Control button but this command does not work for MUTE ON Acceptable ACK CR Response Unacceptable CR 7 14 Video Mute ON Command Command C0D CR Detail Video Mute ON T...

Page 10: ...age to High contrast mode Acceptable ACK CR Response Unacceptable CR 7 20 Image Cinema Command Command C13 CR Detail Set Image to Cinema mode Acceptable ACK CR Response Unacceptable CR 7 21 Image Cust...

Page 11: ...0 CR Detail Brightness of user control 1 Acceptable ACK CR Response Unacceptable CR 7 27 Brightness Command Command C21 CR Detail Brightness of user control 1 Acceptable ACK CR Response Unacceptable C...

Page 12: ...d in EEPROM and even if turning OFF and ON Acceptable ACK CR Response Unacceptable CR 7 33 Power Management Shut Down Command Command C2E CR Detail Set Power Management to Shut down mode This status i...

Page 13: ...as the Remote control s Acceptable ACK CR Response Unacceptable CR 7 39 Pointer Left Command Command C3B CR Detail Move Pointer to left On Screen Display Menu This command works the same as the Remote...

Page 14: ...4 Freeze OFF Command Command C44 CR Detail Return to Freeze OFF screen This command works the same as the Remote control s FREEZE button Do not work the Freeze ON Acceptable ACK CR Response Unacceptab...

Page 15: ...Presentation Timer Command Command C8A CR Detail Set a presentation timer to active This command works the same as the Remote control s P TIMER button Acceptable ACK CR Response Unacceptable CR 7 50...

Page 16: ...Example Get input mode for the projector by basic commands COMMAND current input mode command issue PC Projector C R 1 CR Projector PC 1 CR Response A few ms 1s Shows Computer is selected 8 3 Status R...

Page 17: ...time defers from models This Cooling Down Works for lamps and other optical accessories Control commands are not available for this status 5 10 CR Status Abnormal power supply voltage When the power s...

Page 18: ...ement function is ON in setting menu and there is no signal for 5 minutes it moves on to PowerSave status after PowerSave and Cooling Down Moving on to the status of Power On is the same action as mov...

Page 19: ...3 1 Temperature sensor 1 2 Temperature sensor 2 3 Temperature sensor 3 Temperature data form shows as 00 0 When the temperature sinks to the first character is like 05 5 CR When cannot return the tem...

Reviews: