![background image](http://html.mh-extra.com/html/canon/l1/l1_service-manual_61348019.webp)
2-8
2-8
2
2
Technology
Technology
Original size detection position
In main scanning direction, the machine moves the scanner unit to the following position in
reference to the original position and measures the CMOS level of each detection position. In
sub scanning direction, original size is identi
fi
ed by the following sensors.
A5
A5-R
A4-R
A4
A3
B4
B5
B5-R
20 mm
30.0 mm
146.0 mm
169.0 mm
178.0 mm
197.0 mm
206.0 mm
Original
size sensor 1 (CF1)
B6
0 mm
239.5 mm
244.0 mm
253.0 mm
284.0 mm
293.0 mm
Original
push-on position
Scanner unit
original detection position
■
STMT-R
LETTER_R
LEGAL
LETTER
LEDGER
Original
push-on position
20 mm
30.0 mm
126.7 mm
135.7 mm
211.9 mm
STMT
0 mm
311 mm
264.0 mm
267.0 mm
Original
size sensor 2 (CF2)
Scanner unit
original detection position