CHAPTER 5 SERVICE MODE
5-75
E355-CLR
---
PWD-CLR
Use it to clear the password of the system administrator in user mode.
Using the Mode
1) Select <PWD-CLR> to highlight, and press the OK key.
2) Turn off and then on the main power switch.
ADRS-BK
Use it to clear the address book data.
Using the Mode
1) Select <ADRS-BK> to highlight, and press the OK key.
2) Turn off and then on the main power switch.
CNT-MCON
Use it to clear the counters for servicing on the main controller PCB.
Using the Mode
1) Select <CNT-MCON> to highlight, and press the OK key.
2) Turn off and then on the main power switch.
CNT-DCON
Use it to clear the counter for servicing on the DC controller PCB.
Using the Mode
1) Select <CNT-DCON> to highlight, and press the OK key.
2) Turn off and then on the main power switch.
MMI
Use it to clear the backup data for the user mode settings (specifications, ID
mode, group ID, mode memory, etc.).
Using the Mode
1) Select <MMI> to highlight, and press the OK key
2) Turn off and then on the main power switch.
CARD
Use it to clear the card (group) ID-related data.
Using the Mode
1) Select <CARD> to highlight, and press the OK key.
2) Turn off and then on the main power switch.
ALARM
Use it to clear the alarm log.
Using the Mode
1) Select <ALARM> to highlight, and press the OK key.
2) Turn off and then on the main power switch.