CHAPTER 1 MAINTENANCE AND INSPECTION
1-6
4 Scheduled Servicing Chart
Do not use solvents or oils not indicated herein.
4.1 Reader Unit
: Clean : Replace ×: Lubricate : Adjust : Inspect
T01-401-01
Part
Scanner cable
Scanner rail
Copyboard glass
No. 1 through No. 3
mirror
Original illumination
reflecting plate
Original size sensor
Lens
Unit
Scanner
Optical unit
Upon
installation
Maintenance intervals
Remarks
Silicone oil
(S20; FY9-6011)
every 120,000
×