![Canon imgaePRESS 1110+ Customer Expectation Document Download Page 18](http://html.mh-extra.com/html/canon/imgaepress-1110/imgaepress-1110_customer-expectation-document_2553044018.webp)
Version 3
imagePRESS 1110+ Customer Expectations Document
Page 18
IMPORTANT
•
We recommend an additional standard 120 V/15 A outlet for service tools, such
as a laptop computer or vacuum that may be used when servicing or configuring
the machine.
•
Use only dedicated outlets for the main unit and each optional accessory. Do not
use extension cords.
NOTE
The Puncher Unit-BS1, Color Image Reader-L1 with feeder, Paper Folding
Unit-F1, and Booklet Trimmer-D1 do not require any additional outlets.
The following illustration shows the relative position of the power outlets, and
voltage requirements of each optional accessory item.
IMPORTANT
•
Phase converters and step down transformers are not supported.
•
Canon USA strongly recommends that dedicated and properly grounded outlets
be provided for the devices mentioned above. The ground connection serves to
provide the internal electronics with a reference voltage. Faulty or poor ground
sources will cause this reference voltage to fall into a range that no longer serves
as a reliable reference voltage. The internal logic and programming of the
imagePRESS 1110+ will not perform reliably because there is an insufficient
difference between the internal operating signal voltages and the poor ground
reference signal. A qualified electrician can measure and provide the ground
source that the imagePRESS 1110+ or any computer controlled office equipment
requires.
•
Before installation, confirm that all necessary receptacles are available.