COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON iR8500 REV.0 MAR. 2001
CHAPTER 6 TROUBLESHOOTING
6-119
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J2
ADF
controller
PCB
Delivery motor (M5)
2) Disconnect the connector (J2) from the ADF controller PCB.
Set the meter range to × 1
Ω
Ω
Ω
Ω
Ω
, and connect the meter probes as indi-
cated. Is the resistance about 15
Ω
Ω
Ω
Ω
Ω
?
F06-401-09
NO:
Replace the delivery motor (M5). After replacement, be sure to per-
form “Adjusting the Sensor and the Delivery Motor.”
Delivery Motor Clock Sensor (PI11)
ADF controller PCB
3) Set the meter range to 10 VDC. Turn the delivery motor by hand.
Does the voltage between connectors J3-2 (+) and J3-1 (–) on the
ADF controller PCB change between 0 V and 5 V?
NO:
Replace the delivery motor clock sensor (PI11).
YES: Replace the ADF controller PCB.