Removing the Separation Pad
1)Open the feeder cover.
2)Remove two hooks to remove the separation pad.
x2
NOTE:
When replacing the consumable parts, be sure to clear the parts counter.
(Lv1.COPIER > COUNTER > DRBL-2 > DF-SP-PD)
F-4-50
F-4-51
Replacing the Stamp
CAUTION:
If the stamp is floating, a jam can occur. Be sure to push in the stamp until it clicks.
1)Open the feeder cover and separation guide.
2) Using tweezers, remove the stamp
3)Using tweezers or the like, attach a new stamp.
Be sure to attach the new stamp with the stamp face up.
4)Close the feeder cover and separation guide.
NOTE:
When replacing the consumable parts, be sure to clear the parts counter.
(Lv1.COPIER > COUNTER > DRBL-2 > STAMP )
F-4-52