Adjustment After Replacing the Parts
In case of removing the parts as shown below, adjust the following item.
Parts to replace
Adjustment item
Reference
Motor/Other roller
Adjusting the Magnification
“Adjusting the Magnification” on page 103
Adjustment
In case of removing this equipment and then re-installed, adjust it in order as shown below.
No.
Adjustment item
Reference
1
Adjusting the Height
“Adjusting the Height” on page 70
2
Adjusting the Perpendicularity
“Adjusting the Perpendicularity” on page
74
3
Adjusting the Reading Position
“Adjusting the Reading Position” on page
78
4
Adjusting the Magnification
“Adjusting the Magnification” on page 79
5
Adjusting the Image Position (Horizontal Scanning Direction)
“Adjusting the Image Position (Main Scan-
ning Direction)” on page 80
6
Adjusting the Image Position (Leading Edge)
“Adjusting the Image Position (Sub Scanning
Direction)” on page 81
7
Adjusting the White Level
“Adjusting the White Level” on page 82
Preparation or Creation of Test Chart
Prepare a test chart. If there is no test chart, create a test chart.
Create a test chart that has a 10 mm smaller rectangle from the edge of A4 or LTR paper.
NOTE:
Be sure to write a character or mark to identify the printed image direction.
10 mm
10 mm
10 mm
10 mm
5. Adjustment
69
Summary of Contents for DADF-AV1
Page 1: ...Revision 2 0 DADF AV1 Service Manual ...
Page 9: ...Product Overview 1 Features 4 Specifications 5 Name of Parts 6 ...
Page 39: ...Periodical Service 3 List of Work for Servicing 34 ...
Page 74: ...Adjustment 5 Overview 69 Basic Adjustment 70 ...
Page 113: ...APPENDICES Service Tools 108 General Circuit Diagram 109 ...