Setting Page
5
155
The timer function can generate events that can trigger operations, such as video recording and e-mail notifications, at
regular intervals.
You can set the following two types of timers.
• 24 hours continuous from specified time
• Within specified time only
Either type can be set to trigger timer events at regular intervals.
Timer 1 to 4
You can register up to four timer events.
[Timer Event]
Select whether to use a timer event.
[24-Hour Continuous Settings]
When set to [Enable], the timer event will be repeated at the interval in [Repeat Interval] for 24 hours, starting from the time
specified in [Start Time].
When set to [Enable], only [Video Record] operations can be performed.
[Start Time]
Enter the start time of the timer event in 24-hour format. The timer event will be triggered at the start time.
[End Time]
When [24-Hour Continuous Settings] is set to [Disable], enter the end time of the timer event in the 24-hour format.
[Repeat Interval]
Select a repeat interval for timer events. The timer event will be triggered at the selected intervals.
Operation
Set the operations to be performed when timer events are triggered.
[Start Time Preset]
When [24-Hour Continuous Settings] is set to [Disable] and you specify a preset, the camera angle will automatically move
to the preset location at the time set in [Start Time].
It is necessary to set presets beforehand with [Camera] > [Preset] (P. 118).
[Video Record]
Select whether to record video depending on the timer event.
[Event] > [Timer]
Timer Triggered Operation Settings
Important
When the camera is moved to a preset position specified in the [Start Time Preset] settings, camera control privileges are released, even
if the user has obtained those camera control privileges using the Camera Viewer or other camera control applications.
The following settings can be configured here.
• Timer 1 to 4
• Operation
HM4x S30 S31
HM4x S30 S31