Cannon Fitzroy Inbuilt Power Flue | 17
serViCe instrUCtions (Do not MoDify tHis aPPlianCe)
To Replace The Burner And Spark/Sense Electrodes
1. remove the logs from the burner chamber.
2. remove the burner chamber front panel, 7 screws.
3. Disconnect the 16mm nut at the inlet of the injector.
4. Disconnect the spark and sense electrodes from the
ignition module.
5. remove the 2 M5 wing nuts from under the burner.
lift the burner assembly upward and carefully remove
from the burner chamber.
6. replace in reverse order, checking correct location of
spark/sense electrodes. Spark gap between electrode
and spark plate is 6 - 8 mm. Flame sense electrode
must be in constant flame. Check for gas tightness.
For log placement refer page 14 of this manual.
To Replace The Combustion Fan (Fig 38)
The Combustion Fan is accessed from the rear of the
heater. Therefore to replace the combustion fan the
heater must be removed from the fireplace. The flue
terminal may need to be removed from the flue hoses
to allow the heater to be moved.
1. remove the rear cover
2. Disconnect combustion fan wiring from loom.
3. remove the rear cover.
4. remove the four (4) screws securing the fan to fan duct.
5. remove fan assembly from fan duct.
6. replace in reverse order.
To Replace The Electronic Controller
1. remove the fascia. refer to page 13 of the
installation booklet
2. Disconnect the plugs on box.
3. remove the screw retaining the bracket
4. replace the control box
5. Check and re-set gas pressures.
To Replace Power Cord
Contact Sampford IXl service department.
fig 38
removing Combustion Fan
Flame Sense
Electrode
fig 37
Clear Silicon Tube
Black Silicon Tube
fig 36
room fan
fig 39
Securing the burner bed