8 | Cannon Fitzroy / Canterbury Inbuilt

Any service requests resulting from incorrect instal-
lations are not covered by our warranty conditions 
and these calls will result in charges, usually to the 
end user, so please ensure that the installation and 
commissioning has been satisfactorily carried out 
before calling for any warranty service.

Please make sure that your customer is fully instructed on 
how to operate the heater.

Clearances

For minimum clearances refer 

FIG 5 

and

 FIG 6

.

A clearance of 50 mm must be maintained between 
the cabinet and the rear wall of the fireplace. 

ensure the minimum clearances to combustible  
materials are maintained during installation, including 
adequate space for the proper operation and servicing  
of the heater. For clearances to furniture and curtains 
refer to warning on page 3 (Safety Warnings) 
note: ensure that the combustion air opening under the 
heater is not obstructed.

The clearance is required for correct fluing of 
the appliance. If the clearance is less than 50mm 
a spacer kit must be fitted. The spacer can be 
ordered from the Cannon distributor.
Installation Into A Masonry/Brick Or Mock Fireplace 

both models FItzIb & CantIb can be installed into a 
masonry/brick fireplace or a mock fireplace. If install-
ing into a mock fireplace a mock fireplace installation kit 
MuSt be used. the mock fireplace kit can be ordered 
from the CannOn distributor. Order specification for the 
part is ‘MOCKKItunI’.
For installation into a masonry or brick fireplace WItH  
a flue connection, refer 

FIG 9

. For installation WItH-

Out refer 

FIG 7

 & 

FIG 8

. after installation of the heater, 

test the flue to confirm air vents are unobstructed. If an 
exhaust fan or other heating/ventilation appliances are 
present, switch them on. this is to test and ensure that 
there is no interaction between the Cannon heater and 
other appliances.

Refer to Australian Standard Gas Installations AS 5601: 
For ‘air movement not to affect appliance’ see clause 
5.3.1. 
For ‘air supply to appliance’ see clause 5.4.1. 
For ‘ventilation requirements’ see clause 5.4.3.

fitzroy & Canterbury inbuilt installation instruCtions

Overview

1.  this appliance is to be installed by an authorised serv-

ice person only. 

2.  this appliance shall be installed in accordance with the 

manufacturer’s installation instructions, local gas fitting 
regulations, municipal building codes, electrical wiring 
regulations, and aS5601 the australian Standard for 
gas installations. 

3.  remove the heater from the carton and remove  

the four transit screws. Check that the heater is suita-
ble for the gas available. refer to the data label located 
within the fan chamber (bottom most area with fascia 
removed). (Please dispose of packaging appropriately, 
keep away from children). 

Installation Tips

test the operation of the chimney before installing the 
new heater.
CannOn heaters are high efficiency products with low 
flue gas temperatures (typically 100°C) so if you are 
replacing an older type radiant heater with a much higher 
flue gas temperature (150°C or higher) make sure of the 
integrity of the fireplace and chimney before installing the 
new CannOn log fire.
a solid, levelled and smooth base is required  
(fill gaps with fibreglass insulation if necessary).
avoid installing into large volume fireplaces and chimneys 
and not fitting a flue. 
We recommend cleaning or sweeping the chimney and 
fireplace before the installation of the heater commences.
there must be a good seal around the heater, gas piping 
and electrical cable rear entry to stop any leakage of 
combustion products. Do not use adhesives or silicone 
sealant, the heater must be able to be easily removed  
if necessary.
Install a chimney plate and cowl to the chimney opening 
using weatherproof mortar to common building practice.
remove any curved fire wall that slopes too far forward 
to the fireplace opening as it causes restriction to the flue 
path above the heater flue outlet. refer 

FIG 7

 & 

FIG 8

.

Make sure that the heater is fully commissioned and be 
certain to conduct a test of the integrity of the flue opera-
tion, taking into account any influences created by range 
hoods, exhaust fans, central heating, etc.
to avoid any unnecessary delays and inconvenience to 
your customer please contact our technical Services 
Department on 1300 727 421 if the installation is unusual 
or you have concerns with the installation and/or heater 
operation before the installation commences.

Summary of Contents for CANTERBURY

Page 1: ...n Manual Please read this manual before installing and using this heater Please leave instruction manual with the owner Distributor This appliance is designed manufactured and distributed by Tel 1300 727 421 Fitzroy Canterbury ...

Page 2: ...original purchase We will at our option and subject to the terms of this warranty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or manufacturing However this warranty does not cover any consumables if any The purchaser must present the original purchase receipt to us wh...

Page 3: ... no part of it should be permanently removed For protection of young chil dren or the infirm a secondary guard is required This appliance meets the following standards Standards Australia AS NZS 3100 AS 5601 AS 4553 2008 Safety Warnings Please read this manual before installing and using the heater Safety Warnings 1 Improper installation adjustment alteration service or maintenance can cause injur...

Page 4: ...N OFF button once to restart the heater during this time Wait at least 20 seconds before attempting to turn the heater on OperatiON ON OFF LOW HIGH MEDIUM FIG 2 FIG 1 If there is an interruption to the power supply the heater will fail safely and switch off When the power supply has been restored adopt the 20 seconds waiting rule before turning the heater ON Cleaning All cleaning should be carried...

Page 5: ...inless steel Canterbury mesh kit CANTIBMG B Remote Thermostat RTKIT Versatility and flexibility are key components of our instal lation options If installed into a shallow recess or an existing fireplace elegant spacers will eliminate any size discrepancies To enhance your Cannon s appearance add a decorative 3 or 4 sided surround Every Cannon heater brings you the optional convenience of being co...

Page 6: ...an 3 speed Ignition Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity dimensions Height 605 mm Width 700 mm Depth 405 mm Optional accessories Glass front Remote thermostat Spacer kit 3 sided surround 4 sided surround Console kit Overall dimensions Refer to FIG 3 For installation into a non combustible fireplace ie masonry or brick Please Note W...

Page 7: ...ssure at burner high setting Natural gas 0 75 kPa Propane gas 2 65 kPa Gas regulator Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity dimensions Height 605mm Width 700mm Depth 385mm Optional accessories Safety mesh guard Remote thermostat Spacer ki...

Page 8: ...nstructions Overview 1 This appliance is to be installed by an authorised serv ice person only 2 This appliance shall be installed in accordance with the manufacturer s installation instructions local gas fitting regulations municipal building codes electrical wiring regulations and AS5601 the Australian Standard for gas installations 3 Remove the heater from the carton and remove the four transit...

Page 9: ... 655 mm 600 mm Ceiling Mantle 300 mm min clearance 900 mm min clearance Rear wall 380 mm 1000 mm min clearance 50 mm clearance For installations in non combustible enclosures For installations in non combustible enclosures Mock Fireplace Opening Combustible materials Fitzroy Inbuilt Canterbury Inbuilt Max Min Max Min Height 650 mm 630 mm 654 mm 630 mm Width 780 mm 731 mm 790 mm 731 mm Depth 600 mm...

Page 10: ...bends FIG 9 Be careful Installing a flue on the shorter wall may subject it to down draughts or reverse air flows through the heater which can be difficult to find a solution to Always adopt correct flue design practices In windy locations consider installation of a powerflue version heater or at least an anti down draught cowl to reduce any flue operation problems The heater has been tested and s...

Page 11: ... FIG 16 FIG 13 FIG 17 FIG 14 FIG 11 To fully remove the fascia unclip the switch cable from the cable connector on the PCB and unclip the cable from the clipping points on the rear of the fascia 1 To remove the inner fascia assembly undo two screws in the upper flange as indicated in FIG 12 Remove the inner fascia assembly by holding the glass surround and firmly pull it towards you Refer FIG 13 2...

Page 12: ...al this is especially important when the installation is in a chimney with no flue fitted to eliminate the possibility of any leak age of flue products into the room A suitable double pole isolation switch must be installed externally for servicing or emergency shut down of the heater All fixed wiring must be installed by a suitably qualified person and comply to the appropriate electrical wiring ...

Page 13: ...r glass making sure not to over tighten the screws 4 Reconnect switch loom to the fascia switch set 5 Replace the fascia GAS CONNECTION FIG 22 FIG 23 FIG 25 FIG 24 1 Push the gas inlet access plate into the heater cabinet and slide the heater into the fireplace ensuring that the gas inlet pipe is fed through the hole located at the rear right hand side of the heater at the bottom Refer FIG 26 2 Wi...

Page 14: ...control to give a pressure reading of 0 4 kPa for Natural Gas and 1 1 kPa for LPG Turn clockwise to increase pressure and anticlockwise to decrease pressure Refer FIG 31 5 Remove spanner and screwdriver Switch from high to low to ensure settings are correct 6 Switch heater off and remove the manometer tube Tighten pressure test point by turning the captive screw fully clockwise 7 Replace plastic c...

Page 15: ...an is spin ning refer to fault codes on page 18 General 1 Service work to be carried out by an authorised service person only 2 Unplug from wall socket or turn off power at isolation switch if heater is hard wired 3 Always shut off the gas supply and ensure that the heater is cool before commencing any service operations 4 Always check for gas soundness after servicing To Replace The Inner Glass R...

Page 16: ...move the burner chamber front inspection panel 4 screws 3 Disconnect the 16mm nut at the inlet of the injector 4 Disconnect the spark and sense electrodes from the ignition module 5 Remove the burner fixing brackets 2 from the Left and Right hand side of the burner Lift the burner assembly upward and carefully remove from the burner chamber 6 Replace in reverse order checking correct location of s...

Page 17: ... ON OFF LOW BRN LOW FAN MED BRN MED FAN HIGH BRN HIGH FAN SHEATHED HIGH TEMP DATA CABLE SWITCH BLUE 4 WAY 2 WAY 6 WAY 3 WAY EARTH RED 1 WAY C ROOM FAN F3594 240 V MAINS PLUG BROWN BLUE MODULATING VALVE F3691 COILS FLAME SENSOR SPARK ELECTRODE IGNITION MODULE F3833 PRESSURE SWITCH F3327 ROOM AIR FAN NO C 2 WAY 4 WAY 2 WAY NC RED RED BLUE RED EARTH F3835 A CONTROL MODULE F3828 ...

Page 18: ... of the pressure switch and to the top tapping on the venturi Make sure that the pressure switch wires are connected correctly One wire should be to C Common and the other should be to NO Normally Open If it still doesn t work after checking the above change the pressure switch To check the operation of the heater s electrical system you will require a digital multimeter with the functions to meas...

Page 19: ...de of the pressure switch to the bottom tapping on the fan venturi The clear tube should go from the light side of the pressure switch and to the top tapping on the venturi Make sure that the pressure switch wires are connected correctly One wire should be to C Common and the other should be to NO Normally Open If it still doesn t work after checking the above change the pressure switch 2 8 Room f...

Page 20: ...led Compliance Certificate No Installed by COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the relevant standards And only a licensed person will have insurance protecting their workmanship for 6 years So make sure you use a licensed person to install this appliance and ask for your comp...