12 | Cannon Canterbury Freestanding
Electrical Connection
This appliance is designed to operate on 240v AC power
supply. Failure to operate unit at correct supply voltage
may create unsafe conditions.
The heater is supplied with a flexible power cord with
a plug fitted. A 10 Amp switch socket must be located
within 1.5m of the heater.
A suitable double pole isolation switch must be
installed externally for servicing or emergency shut
down of the heater.
All fixed wiring must be installed by a suitably qualified
person and comply to the appropriate electrical wiring
rules.
It is critical that the appliance is earthed and that
the active and neutral are not reversed. Issues
arising from incorrect electrical wiring at premises
will not be covered under warranty (including use
of extension cords). We recommend that the heater
is connected directly to a switch socket by its own
power cord. Refrain from using extension leads.
ElECTriCal CONNECTiON
gaS CONNECTiON
Connect incoming gas supply pipe to 1 / 2 ” compression
fitting at rear of appliance. For inlet position refer
FIG 11
.
Solid copper pipe to be used only.
Heater is not to be connected using a flexible hose.
fig 11
125mm
110mm