background image

Cannon Canterbury Freestanding | 3

warraNTy

This Warranty against defects for your newly purchased 
Cannon product is proudly prepared by Sampford IXl Pty 
ltd of 421 Smith Street, Fitzroy, vIC 3065,  
phone 1300 727 421.
1.   Sampford IXl products come with guarantees that do 

not exclude the following consumer entitlements under 
the Australian Consumer law:

  a.   replacement or refund for a major failure and 

compensation for any other reasonably foreseeable 
loss or damage; and

  b.   to have the goods repaired or replaced if goods fail 

to be of acceptable quality and the failure does not 
amount to a major failure.

2.   Sampford IXl warrants that your product and related 

supply will be free from defects in materials and 
workmanship during the warranty term.  
your warranty term can be found in your original 
instruction booklet contained in this box, 
commencing from the date of purchase. Sampford 
IXl acknowledges this product requires professional 
installation and product removal is hazardous to 
consumers, accordingly any necessary inspections 
and services will be carried out on site. you should not 
attempt de-installation.

3.   Subject to Point 1, Sampford IXl will repair any defects 

in materials and workmanship during the warranty 
term and if the product is deemed irreparable provide 
a replacement of an equivalent current model where 
the balance of the warranty period from the original 
date of purchase will take effect.

4.   To the fullest extent permitted by law and subject 

always to Point 1, Sampford IXl will not be liable for:

  a.   any loss or damage arising from loss of use, loss 

of profits or revenue; or

  b.   for any indirect or consequential loss or damage 

resulting from any breach of this warranty  
against defects.

5.   Defective Sampford IXl products may be repaired 

using refurbished parts or if required, completely 
replaced by a refurbished product of the same type.

Limitations to Your Cannon Warranty

6.  Subject to Point 1, this Warranty:
  a.   will only be provided to the original purchaser 

where the original purchase was made from a 
Sampford IXl Authorised Dealer or reseller and 
proof of such purchase can be presented at the 
time of service;

  b.   only applies to Sampford IXl products purchased 

in Australia from a Sampford IXl Authorised Dealer 
or reseller and installed by a qualified person 
where a Certificate of Compliance in accordance 
with State/Territory laws is provided;

  c.   will not apply where the defect in or failure of 

the product is attributable to misuse, abuse, 
accident or non-observation of the manufacturer’s 
instructions. This product must be used in 
accordance with the manufacturer’s instructions;

  d.   will not cover faults due to normal wear and tear 

with reasonable use nor consumable components 
such as globes, filters, glass items, etc;

  e.   will not cover any damages or problems caused to 

this product by natural forces eg. storm, fire, flood, 
and earthquake; or by intrusion or accumulation 
(or both) of foreign matters eg. dust, soil, and 
moisture. Sampford IXl recommends that you take 
out appropriate insurances to protect your product 
to this end;

  f.   will not apply if this product is installed in a mobile 

dwelling eg. caravan or boat;

  g.   will not apply if this product is removed from the 

location where it was first installed;

  h.   is immediately void if the serial or model number 

label is removed or defaced;

  i.   is immediately void if the product is serviced or 

repaired by a unauthorised/unqualified personnel;

  j.   covers use of this product for domestic use only;
  k.  will not be restarted or extended upon repair or  
   

replacement of the product or a part.

How to Make a Claim Under Your Cannon Warranty

7.  To make a claim under this Warranty you will need to:
  a.   contact Sampford IXl service department on  

1300 727 421 or aftersalesservice@sampfordixl.
com.au to provide details and register your claim 
enabling a Sampford IXl assessment;

  b.  submit proof of purchase with your claim  
   

eg. tax invoice or purchase receipt;

  c.   where a property has been constructed by a 

builder/developer and it is fitted with IXl products, 
please submit proof of purchase by way of the 
certificate of occupancy, with your claim.

8.  Sampford IXl will contact you to make arrangements 
  for service on site.
9.   Subject to Point 1, you will be responsible for any 

costs relating to the provision of your product to a 
Sampford IXl Authorised Service Dealer.

10.  Subject to Point 1, in the event you live more than  

50 km from a Sampford IXl Authorised Service Dealer 
you may be subject to travel or transport costs to 
facilitate the repairing or replacement of your  
IXl product.

Summary of Contents for Canterbury CANTFS-SDE

Page 1: ...e read this manual before installing and using this heater Please leave instruction manual with the owner Model CANTFS SDEEB Distributor This appliance is designed manufactured and distributed by Tel...

Page 2: ...nterbury FREESTANDING specifications 8 CANTERBURY FREESTANDING INSTALLATION INSTRUCTIONS 9 FRONT GLASS Removal AND INSTALLATION 10 Flueing Installation 11 Electrical Connection AND GAS CONNECTION 12 L...

Page 3: ...products purchased in Australia from a Sampford IXL Authorised Dealer or Reseller and installed by a qualified person where a Certificate of Compliance in accordance with State Territory laws is prov...

Page 4: ...pray aerosols near this appliance DO NOT operate with panels covers or guards removed from this appliance DO NOT connect an LP gas cylinder located indoors 11 Sampford IXL and its Authorised Service D...

Page 5: ...windows d Do not touch electrical switches e Do not use your telephone f Call your gas supplier immediately from a neighbour s phone 2 Improper installation adjustment alteration service or maintenanc...

Page 6: ...mpts to ignite the heater without success OperatiON ON OFF LOW BOOST NORMAL FIG 2 FIG 1 If there is an interruption to the power supply the heater will fail safely and switch off When the power supply...

Page 7: ...remote thermostat For added convenience the heater can now be connected to a home automation system such as C bus This allows the heater to be turned on or off remotely normal heat setting only Speak...

Page 8: ...ower requirement 240 VAC 10 Amp switch socket Power consumption 90 VA maximum Optional accessories Clip on mesh safety guard Cathedral ceiling flue box Remote control thermostat Flue kit purchase sepa...

Page 9: ...e heater is fully commissioned and be certain to test the integrity of the flue operation taking into account any influences created by range hoods exhaust fans central heating etc Any service request...

Page 10: ...irmly on either side and pulling it towards yourself Refer FIG 6 3 Remove the inner glass Slacken off screws in top clamp and remove side clamps Refer to FIG 7 To Refit The Front Glass Surround Ensure...

Page 11: ...eiling Please note If the ceiling has an incline the ceiling box will need to be fitted The ceiling box is an accessory and can be ordered from the supplier Installation instructions are supplied with...

Page 12: ...y a suitably qualified person and comply to the appropriate electrical wiring rules It is critical that the appliance is earthed and that the active and neutral are not reversed Issues arising from in...

Page 13: ...must engage with corresponding holes in the individual logs a Place log 1 into the 2 front left pins on the burner bed ensuring that the charring faces the front Refer FIG 13 b Place log 2 onto the 2...

Page 14: ...ol to give a low pressure reading refer to spec table on page 8 Turn clockwise to increase pressure and anti clockwise to decrease pressure Refer FIG 21 5 Remove spanner and screwdriver Switch from hi...

Page 15: ...rt If the heater fails to light even when the fan is spinning refer to fault codes on page 18 General 1 Service work MUST be carried out by an authorised service person only 2 Unplug from switch socke...

Page 16: ...making sure that the black tube attaches to the black side of the pressure switch Make sure that the tubes are not pinched or kinked 8 Test operation of fan pressure switch turn heater on low heat If...

Page 17: ...5 AMP 18 ON OFF LOW BRN LOW FAN MED BRN MED FAN HIGH BRN HIGH FAN SHEATHED HIGH TEMP DATA CABLE SWITCH BLUE Y A W 4 Y A W 6 Y A W 3 EARTH RED Y A W 1 C ROOM FAN F3594 240 V MAINS PLUG MODULATING VALV...

Page 18: ...has attempted to light however it did not sense flame within the allowed time Check the gas supply to the unit is not switched off Check the gas pressures Check the flame and spark electrode connectio...

Page 19: ...of the pressure switch to the bottom tapping on the fan venturi The clear tube should go from the light side of the pressure switch and to the top tapping on the venturi Make sure that the pressure sw...

Page 20: ...Compliance Certificate No Installed by COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all...

Reviews: