background image

 

 

 

 

 

 

Operation of wireless remote control

 

 

Names and functions of wireless remote control

 

 

Notice: This is a general use remote controller, it could be used  for  the air conditioners 
with multifunction; For some  function, which the model dosen't have, if press the 
corresponding button on the remote controller that the unit will  keep the original 
running  status.

 

Remote control

 

TEMP

 

BLOW

 

",

 

the drying.In Cool and Dehumidifying mode,

 

 

this button,"BLOW" will be concealed, at

 

switching mode to Cool or Dehumidifying

 

status. If unit is turned off, Blow OFF only

 

 

can not be set up and there is no "BLOW"

 

)

 

 

 

 

TURBO

 

can turn on or turn off the Turbo function.

 

signal will be displayed. When switching

 

function will be canceled automatically.

 

7

 

+

 

+ button

 

 

●  

For presetting temperature increasing. 
Press this button,can set up the temperature, 
when unit is on . Continuously  press and 
hold  this button for more than 2   seconds, 
the corresponding contents will   be

 

changed  rapidly, until unpress the button 
then send the information, 

℃(℉)

is disp-

 

laying all along. In Auto mode, the temp- 
erature can not be set up, but operate this 
button can send the signal. Centigrade 
setting range :16-30; Fahrenheit scale 
setting range 61-86.

 

 

TEMP button

 

 

 

● Press  this  button, could select  displaying  the 

indoor setting temperature or indoor ambient 
temperature.When  the  indoor  unit  firstly 
power  on  it  will  display  the  setting 
temperature, if the temperature's displaying

 

status is changed from other status to" 

displays the ambient temperature, 5s later or 
within 5s, it receives other remote control signal 
that will return to display the setting 
temperature. if the users haven't set up 
temperature displaying status,that will 
display the setting temperature.

 

(This function is applicable to partial of models)

 

● After powered on, the setting temperature

 

displaying is defaulted, (according to 
customers requirements to display,  if 
there is no requirement that will default to 
display  the presetting temperature and 
there is no icon displayed on remote 
wireless control). Press this button,

 

(When displaying 

) , will display 

presetting temperature; (when displaying will 
display indoor  ambient temperature,

 

current displaying status will not be 

changed. If current displays indoor ambient 
temperature, if received the remote control  
other signal, it will display presetting 
temperature, 5s later, will back to display 
the ambient temperature.

 

(This function is applicable to partial of models)

 

 

BLOW button

 

 

 

●  

Press this button, can turn on or turn off

 

 

press this button and will display "BLOW", 
at this time the Blow is turned on. If repress

 

 

this time the Blow function is turned off. 
After powered on, Blow OFF is defaulted. 
When operating the ON/OFF button, or

 

mode,the Blow function will keep the original 

can be set up and send the signal. In Auto,

 

Fan as well as Heat mode, Blow function

 

 

displaying.

 

 

-

 

- button

 

 

 

●  

Presetting temperature can be decreased.

 

Press this button, the temperature can be 

set up, continuously press this button 
and hold for two seconds, the relative 
contents can quickly change, until unhold

 

this button and send the order that the 

 

o

F)  signal will be displayed all the time. 

The temperature adjustment is unav- 
ailable under the Auto mode, but the order 
can be sent by if pressing this button.

 

 

 

TURBO button

 

 

●  

In Cool or Heat mode, press this button

 

After turned on the Turbo function, its 

the mode or changing fan speed, this

 

Summary of Contents for INVERTER SERIES

Page 1: ...or selecting H air conditioners Please read this manual carefully before operation and keep it for further reference C H AIR CONDITIONERS Split Air Conditioner INVERTER SERIES MODELS CH S09FTXG CH S12...

Page 2: ...eal one This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Page 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block...

Page 4: ...ong time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shoc...

Page 5: ...capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high hu...

Page 6: ...utdoor sideDB WB o C Maximum cooling 32 23 48 Minimum cooling 21 15 10 Maximum heating 27 24 18 Minimum heating 20 15 Notices for use The operating temperature range outdoor temperature for cooling un...

Page 7: ...ut The pattern in displayer Cool Dry Fan Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 5 Guide louver 6 Wall...

Page 8: ...ted circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 oF Under other modes the initial value is 25 77 o F...

Page 9: ...e setting temperature if the users haven t set up temperature displaying status that will display the setting temperature This function is applicable to partial of models After powered on the setting...

Page 10: ...umbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer s...

Page 11: ...on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running...

Page 12: ...inished Operation of this function on or off If remote controller is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is unde...

Page 13: ...he front panel Clean the air filter Recommended once every three months NOTE If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter do...

Page 14: ...hether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cle...

Page 15: ...he smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow...

Page 16: ...nsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Page 17: ...e temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much...

Reviews: