Operation of wireless remote control 

Names and functions of wireless remote control

 

 

Notice: This is a general use remote controller, it could be used  for  the air conditioners 
with multifunction; For some  function, which the model dosen't have, if press the 
corresponding button on the remote controller that the unit will keep the original 
running status.

 

 

 

Remote control

 

 

 

8

 

TIMER ON BUTTON

 

TIMER  ON

 

 

● 

Timer On setting: Signal “ON” will blink 

and display, signal 

will conceal, the 

numerical section will become the timer on 
setting status. During 5 seconds blink by 
pressing 

 or 

 button to adjust the time 

value of numerical section, every press of 
that button, the value will be increased or 
decreased 1 minute. Hold pressing 

 or 

button, 2 seconds later it quickly 

change, the way of change is During the 
initial 2.5 seconds, ten numbers change in 
the one place of minute, then the one 
place is constant, ten numbers change in 
the tens place of minute at 2.5 seconds 
speed and carry. During 5s blink press the 
Timer button, the timer setting succeeds. 
The Timer On has been set up repress the 
timer On button, the Timer On will be 
canceled. Before setting the Timer, please 
adjust the Clock to the current actual time. 

 

TIMER OFF

 

 

 

SWING UP AND DOWN BUTTON

 

 

 

 

● 

Press this button, to set up swing angle, 

which circularly changes as below: 

 

 

OFF        

This is an universal use remote controller. If 

remote controller sends the following three 

kinds of status that the swing status of main 

unit will be:     

 

 
 

When the guide louver start to swing up and 

down, if turn off the Swing, the air guide louver 

will stop at current position. 

 

which indicates the guide louver swings up 

and down between that all five positions. 

 

 

TIMER OFF  BUTTON

 

 

● Once  press  this  key  to  enter  into 

TIMER OFF  setup,  in  which  case the 
TIMER OFF  icon  will  blink. The method of 
setting  is  the  same as  for  TIMER  ON. 

 

 

 

  

   

 

   

   

 

 

 

 

Summary of Contents for INVERTER SERIES

Page 1: ...or selecting H air conditioners Please read this manual carefully before operation and keep it for further reference C H AIR CONDITIONERS Split Air Conditioner INVERTER SERIES MODELS CH S09FTXG CH S12...

Page 2: ...eal one This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Page 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block...

Page 4: ...ong time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shoc...

Page 5: ...capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high hu...

Page 6: ...utdoor sideDB WB o C Maximum cooling 32 23 48 Minimum cooling 21 15 10 Maximum heating 27 24 18 Minimum heating 20 15 Notices for use The operating temperature range outdoor temperature for cooling un...

Page 7: ...ut The pattern in displayer Cool Dry Fan Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 5 Guide louver 6 Wall...

Page 8: ...ted circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 oF Under other modes the initial value is 25 77 o F...

Page 9: ...e setting temperature if the users haven t set up temperature displaying status that will display the setting temperature This function is applicable to partial of models After powered on the setting...

Page 10: ...umbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer s...

Page 11: ...on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running...

Page 12: ...inished Operation of this function on or off If remote controller is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is unde...

Page 13: ...he front panel Clean the air filter Recommended once every three months NOTE If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter do...

Page 14: ...hether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cle...

Page 15: ...he smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow...

Page 16: ...nsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Page 17: ...e temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much...