background image

7

EN

Th

e d

at

a a

n

d i

nf

or

m

at

io

n s

h

ow

n i

n t

h

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed b

y C

A

M

E c

an

ce

lli

 a

ut

o

m

at

ic

i s

.p

.a

. a

t a

ny t

im

e w

ith

ou

t p

ri

or w

ar

n

ing

5.3 Dimensions, centre distances and securing holes

117

80

46.5

9.5

37

75.5

50

83.5

38

Intelligent Security & Fire Ltd.

Summary of Contents for WAVE WA01

Page 1: ...WAVE AUTOMATED HOME CONTROL SYSTEM 32 32 C 10 55 10 55 INSTALLATION MANUAL WA01 I n t e l l i g e n t S e c u r i t y F i r e L t d...

Page 2: ...holes 7 5 4 Introduction to the functioning logic 8 5 5 Connecting cables 9 5 6 Wall mounting 10 6 Programming 11 6 1 Description of commands and the display 11 6 2 Browsing the menu 12 6 3 Menu Struc...

Page 3: ...his symbol tells you that the sections concern safety issues This symbol tells you what to say to the end users 2 1 Intended use 2 2 Restrictions Secure the apparatus in areas free from accidental imp...

Page 4: ...ad of accessories 5A 230V AC 24V DC resistant 1 5A 230V AC inductive Protection rating IP40 Isolation class II Temperature variance 1 C Material ABS Support PC PA6 PMMA Plate Radio Frequency 433 92 MH...

Page 5: ...ime without prior warning 6 54 32 32 C 10 55 10 55 4 3 General description 1 2 4 3 5 6 7 1 Temperature gauge sensor 2 Command keypad 3 Display 4 Hole cover plate 5 Power terminals 6 Terminals for conn...

Page 6: ...sure that any connections inside the case that provide continuance to the protective circuit be fitted with extra insulation as compared to the other conductive parts inside Make sure you have suitabl...

Page 7: ...in this manual may be changed by CAME cancelli automatici s p a at any time without prior warning 5 3 Dimensions centre distances and securing holes 117 80 46 5 9 5 37 75 5 50 83 5 38 I n t e l l i g...

Page 8: ...Radio Relay IN OUT Keys Thermostat Timer IN Wave allows you to associate an IN command such as Transponder keys thermostat and timer to an OUT instruction such as a radio code or a relay plug or to t...

Page 9: ...manual may be changed by CAME cancelli automatici s p a at any time without prior warning 6 54 5 5 Connecting cables 230 V a c power source Relay socket Serial connection sockets for WI08 card I n t e...

Page 10: ...e data and information shown in this manual may be changed by CAME cancelli automatici s p a at any time without prior warning EN 5 6 Wall mounting 1 2 3 I n t e l l i g e n t S e c u r i t y F i r e...

Page 11: ...ges Go back in the editable menus The key 32 C 10 55 32 C 10 55 are for Shift from one menu item to another Increase and decrease a value 6 Programming 6 1 Description of commands and display MENU MEN...

Page 12: ...he selected item shift using the ARROWS MENU MENU Setup Setup Edit User Edit User New User Delete User Delete User CONFIRM YES CONFIRM YES New User New User MENU MENU Setup Setup Edit User Edit User N...

Page 13: ...Delete User TX Radio TX Radio Timer Timer Alarm Alarm Thermostat Thermostat Clock Clock Key Function Key Function Password Password Pressing the Enter key for a few seconds takes you into the main men...

Page 14: ...uage ENGLISH ENGLISH FRENCH FRENCH GERMAN GERMAN SPANISH SPANISH NEDERLANDS NEDERLANDS Temperature Temperature Screen Saver Screen Saver Setup Setup ITALIAN ITALIAN 32 C 10 55 Language Language 32 C 1...

Page 15: ...erature Temperature Screen Saver Screen Saver Celsius Celsius Language Language Fahrenheit Fahrenheit Setup Setup 32 C 10 55 Edit User Edit User New User New User 32 C 10 55 32 C 10 55 Select the scre...

Page 16: ...ODE Change user Allows you to change the details of a single user code name kind of exit Setup Setup Edit User Edit User New User New User 32 C 0 55 32 C 10 55 Select the use to change by using the ar...

Page 17: ...hanges keeping it pressed Press ESC 32 C 10 55 to Go back to the previous letter Go back to the previous level without saving any changes keeping it pressed Keep the arrow keys pressed 32 C 10 55 32 C...

Page 18: ...tes a command to a user It can be of two types the first is defined as local exit and is a physical socket NO NC the second is a radio socket up to four different ones can be inserted 6 5 New user Men...

Page 19: ...r Delete User New002 New002 Eliminate User Eliminates a present user SELECT USER SELECT USER New n New n New00 New002 New001 New001 Setup Setup Edit User Edit User New User New User 32 C 10 55 32 C 10...

Page 20: ...IO CHNL RADIO CHNL Delete User Delete User TX Radio TX Radio C 55 Timer Timer 32 C 10 55 From the RADIO TX menu you can associate a CAME transmitter code to an output so as to repeat it and control th...

Page 21: ...which command you wish to associate local output or one of the radio outputs The TIMER lets you associate commands to pre set time intervals then set the deactivation day You will be asked the same in...

Page 22: ...clocks you wish to set You will be asked the time minutes and type of sound Confirm by pressing Enter C 55 Timer Timer 32 C 10 55 Alarm Alarm Thermostat Thermostat ORA ORA 08 08 Timer Timer DISATTIVAZ...

Page 23: ...55 10 55 Once the thermostat is set this symbol will appear on the display The Thermostat allows you to set a temperature interval within which Wave will activate a socket To create a new interval shi...

Page 24: ...ock Clock 32 C 10 55 Key Function Key Function Thermostat Thermostat With the Clock you can set the current time and date on Wave Key Function Key Function RELAY OUT RELAY OUT KEY KEY C 5 Clock Clock...

Page 25: ...C 10 55 EDIT PASSWRD EDIT PASSWRD CODE CODE 2 CODE 1 CODE 1 PSW TRASP 1 PSW TRASP 1 PSW TRASP 2 PSW TRASP 2 32 C 10 55 CODE ODE 1 1 DEL PASSWRD DEL PASSWRD NEW PASSWRD NEW PASSWRD 32 C 10 55 See page...

Page 26: ...4 5678 5678 90 90 1 To confirm the step shift using the ARROW keys onto YES and confirm by pressing ENTER TochoseavalueshiftusingtheARROWkey selectandconfirm by pressing ENTER Repeat the step until yo...

Page 27: ...L PASSWRD To confirm the operation shift using the ARROWS to YES and confirm by pressing ENTER 32 C 10 55 32 C 10 55 32 C 10 55 PSW TRASP 1 PSW TRASP 1 NEW CODE NEW CODE Selecting NEW PASSWORD will br...

Page 28: ...ertified centres after proper collection Other component such as electronic cards batteries and transmitters constitute environmental hazards They must thus be turned in to specialised firms for their...

Page 29: ...r automatic garage doors and gates listed below WA01 comply with the National Law related to the following European Directives and to the applicable parts of the following Standards DIRECTIVES 73 23 C...

Page 30: ...UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431 Cod 119RU27 v 0 1 01 07 CAME cancelli automatici s p a I n t e l l i g e n t S e c...

Reviews: