FEATURES & TERMINOLOGY 

(CONTINUED)

FLOW RATE INFORMATION

FEED WATER PARAMETERS

Total Regeneration

The total number of times the softener has regenerated. 

Historical Total Gallons

Total gallons treated by the softener.

Overrun Total

How many times soft water recharge was required due to high usage.

Current Flow Rate

It will only display if treated water is running, otherwise, it will read  

zero (0).

Valve Mode

Current valve setting, such as Softener Upflow (UF). You can unlock the  

circuit board as directed and press the down arrow to stop the scrolling. 

You can then use the down arrow to go to each of the diagnostics as 

required. 

System Bypass

 

All systems come with a manual bypass valve which allows you to 

bypass the 85UF/DF. This allows raw untreated water to be used in your 

home for any reason, including system servicing. 

Hardness

This can be adjusted seasonally if needed. The installer usually sets this 

for the worst case scenario, where water hardness fluctuates. 

Peak Flow

Maximum flow that has gone through the softener. 

Manual Regen Delay

Generally, used after servicing the valve so that it will regenerate at a 

standard pre-set time.

At the stated service flow rates, the pressure drop through these devices will not exceed 15 psig.
Peak flow rates are intended for intermittent use only (10 minutes or less) and are for residential applications only. Do not use peak flow rate for 

commercial applications or for a continuous rate when treated water supplies are geothermal heat pump, swimming pool, etc.
For satisfactory operation, the pumping rate of the well system must equal or exceed indicated backwash flow rate.

Maximum Iron**

 = 2.0 ppm ferrous (clear water iron)

Maximum Hydrogen Sulfide

 = 0.0 ppm

Maximum Manganese

 = 0.75 ppm ferrous (clear 

water)

pH

 = 6.5 to 8.5 with 

no

 iron or manganese present 

pH

 = 6.5 to 7.5 with iron or manganese present

**See System Maintenance Section - Resin Cleaner

 

NOTE

See 

Start-Up Instructions - Problem Water Injector 

Kit

 if you have iron in your water and are installing an 

upflow water softener.

Summary of Contents for 85UF/DF

Page 1: ...ully before operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is mi...

Page 2: ......

Page 3: ...RATE INFORMATION 8 FEED WATER PARAMETERS 8 UNPACKING INSPECTION 9 BEFORE INSTALLATION 10 PREPARATIONS 11 PLANNING YOUR INSTALLATION 14 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION...

Page 4: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Page 5: ...e Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are located under the salt lid FIND AND RECORD VA...

Page 6: ...43 C or 40 F 110 F Do NOT expose softener to freezing temperatures Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct sunligh...

Page 7: ...nd will be 70 of capacity The unit counts down to the end of the 70 and then calculates how much of the 30 you used reserve It then adjusts the brine amount accordingly and regenerates that evening Th...

Page 8: ...the worst case scenario where water hardness fluctuates Peak Flow Maximum flow that has gone through the softener Manual Regen Delay Generally used after servicing the valve so that it will regenerat...

Page 9: ...m water injector kit is enclosed See Problem Water Injector Kit page for usage information UNPACKING INSPECTION WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after install...

Page 10: ...ces to the pipe as excessive heat can damage them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experie...

Page 11: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Page 12: ...ve the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Page 13: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Page 14: ...in and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plu...

Page 15: ...ector Detail AC 120V 10A Current Protect Socket BrineValve Connector Detail Twin Tank Softener Laundry Stack AC 120V 10A Current Protect Socket Inlet Outlet Optional Overflow Assembly 5 8 Overflow Lin...

Page 16: ...nnections straight or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clip...

Page 17: ...re bypass knobs are completely open otherwise the untreated water may enter through the valve OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEP...

Page 18: ...e 13 Delayed regeneration 14 RegenerationTime time of day when backwash starts 15 Refill time 16 Valve mode 17 Valve ID UNDERSTAND THE SCREEN KEYPAD CONFIGURATION Keypad Legend the terminology used on...

Page 19: ...add salt to the brine tank at this time NOTE If severe loss in water pressure is ob served when the softener unit is initially placed in service the softener tank may have been laid on its side during...

Page 20: ...m Manganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these...

Page 21: ...1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETTINGS m...

Page 22: ...or four 4 key to change WATER SOURCE value For problem water set to WELL OTHER For clean city water choose MUNICIPAL REGEN TIME 02 00 AM LOAD DEFAULT NO REGEN TIME 02 00 PM PROGRAMING COMPLETE 23 Now...

Page 23: ...event bacteria growth from stagnant water This mode is also recommended for filters as certain types of filter media can cement or harden during long periods of non use The factory setting for Smart C...

Page 24: ...LEM WATER INJECTOR KIT For use on upflow softeners only IMPORTANT If the water source this water softener is being applied on is not municipal water and contains up to 2 0 mg l ppm of ferrous Clear Wa...

Page 25: ...ess button two 2 until past PROGRAMMING COMPLETE PRESS SETTINGS KEY 3 SEC TO UNLOCK 1 The display may read PRESS SETTINGS KEY Press button one 1 for three seconds 3 to unlock 2 After three 3 seconds t...

Page 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Page 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Page 28: ...tions happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring th...

Page 29: ...of the holder and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the ResCare bottle on the...

Page 30: ...oz ResCare SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the softene...

Page 31: ...l and repeat until finishing with a seal Important use the specialized end spacer and note it s placement 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston...

Page 32: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Page 33: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Page 34: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Page 35: ...be running at the drain 1 Replace the motor and transformer if unable to determine the output of the transformer separately 2 Contact your authorized installer for parts and or assistance COMMON SPAR...

Page 36: ...any force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of this w...

Reviews: