WARNING

If the ground from the electrical panel or breaker box to the 

water meter or underground copper pipe is tied to the copper 

water lines and these lines are cut during installation of the 

bypass valve and/or poly pipe, an approved grounding strap 

must be used between the two lines that have been cut in  

order to maintain continuity. The length of the grounding 

strap will depend upon the number of units being installed 

and/or the amount of copper pipe being  

replaced with plastic pipe. 

See Figure 1.

 

NOTE

Use of a competent installer or plumbing professional to 

ensure this product is installed in accordance with local  

plumbing codes is recommended. Canature is not liable for any 

non-compliance with local requirements.

MECHANICAL

 

Do NOT use petroleum-based lubricants such as petroleum jelly, oils or hydrocarbon based lubricants. Use only 100% silicone lubricants (packet Part 

#92360 provided in parts kit). All plastic connections should be hand tightened only. Thread tape may be used on connections that do not use an 

O-ring seal.  
Do NOT use pliers or pipe wrenches except when indicated by nut shape, e.g., pipe adapters. All plumbing must be completed according to local 

codes. Soldering connections should be done before connecting any plastic pieces to the pipe as excessive heat can damage them.
Softener resins will degrade in the presence of chlorine or chloramines above one (1) ppm. If you have anything in excess of this amount, you will 

experience reduced life of the resin. Pre-carbon filtration may be required ahead of the water softener to reduce chlorine/chloramine levels

TOOLS REQUIRED FOR INSTALLATION

 

Two adjustable wrenches. 

 

Additional tools may be required if modification to home plumbing is required. 

 

Plastic inlet and outlet fittings are included with the softener. To maintain full valve flow, use of ¾” or 1” [1.9 cm or 2.54 cm]  pipes to   

  and from the softener. You should maintain the same or larger pipe size as the water supply pipe to the softener inlet and outlet. 

 

Use copper, brass, or PEX pipes and fittings. 

 

Some codes may also allow PVC plastic pipe. 

 

5/8”  [15.8 mm] Outside Diameter drain line is needed for the valve drain. 

 

Drain line tubing may be needed for the optional brine tank overflow fitting.

BEFORE INSTALLATION

Make sure you have a copy of your most recent water test results. If your water has not been tested previously, your professional installer can obtain 

a water sample bottle to be sent to one of our facilities for a free analysis. 

It is important that this product not be installed until you have 

this information

In all cases where metal pipe was originally used and is later interrupted by poly pipe, or the Noryl bypass valve, an approved ground clamp with 

physical separation and no less than #6 copper conductor must be used for continuity, to maintain proper metallic pipe bonding.

Summary of Contents for 85UF/DF

Page 1: ...ully before operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is mi...

Page 2: ......

Page 3: ...RATE INFORMATION 8 FEED WATER PARAMETERS 8 UNPACKING INSPECTION 9 BEFORE INSTALLATION 10 PREPARATIONS 11 PLANNING YOUR INSTALLATION 14 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION...

Page 4: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Page 5: ...e Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are located under the salt lid FIND AND RECORD VA...

Page 6: ...43 C or 40 F 110 F Do NOT expose softener to freezing temperatures Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct sunligh...

Page 7: ...nd will be 70 of capacity The unit counts down to the end of the 70 and then calculates how much of the 30 you used reserve It then adjusts the brine amount accordingly and regenerates that evening Th...

Page 8: ...the worst case scenario where water hardness fluctuates Peak Flow Maximum flow that has gone through the softener Manual Regen Delay Generally used after servicing the valve so that it will regenerat...

Page 9: ...m water injector kit is enclosed See Problem Water Injector Kit page for usage information UNPACKING INSPECTION WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after install...

Page 10: ...ces to the pipe as excessive heat can damage them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experie...

Page 11: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Page 12: ...ve the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Page 13: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Page 14: ...in and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plu...

Page 15: ...ector Detail AC 120V 10A Current Protect Socket BrineValve Connector Detail Twin Tank Softener Laundry Stack AC 120V 10A Current Protect Socket Inlet Outlet Optional Overflow Assembly 5 8 Overflow Lin...

Page 16: ...nnections straight or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clip...

Page 17: ...re bypass knobs are completely open otherwise the untreated water may enter through the valve OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEP...

Page 18: ...e 13 Delayed regeneration 14 RegenerationTime time of day when backwash starts 15 Refill time 16 Valve mode 17 Valve ID UNDERSTAND THE SCREEN KEYPAD CONFIGURATION Keypad Legend the terminology used on...

Page 19: ...add salt to the brine tank at this time NOTE If severe loss in water pressure is ob served when the softener unit is initially placed in service the softener tank may have been laid on its side during...

Page 20: ...m Manganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these...

Page 21: ...1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETTINGS m...

Page 22: ...or four 4 key to change WATER SOURCE value For problem water set to WELL OTHER For clean city water choose MUNICIPAL REGEN TIME 02 00 AM LOAD DEFAULT NO REGEN TIME 02 00 PM PROGRAMING COMPLETE 23 Now...

Page 23: ...event bacteria growth from stagnant water This mode is also recommended for filters as certain types of filter media can cement or harden during long periods of non use The factory setting for Smart C...

Page 24: ...LEM WATER INJECTOR KIT For use on upflow softeners only IMPORTANT If the water source this water softener is being applied on is not municipal water and contains up to 2 0 mg l ppm of ferrous Clear Wa...

Page 25: ...ess button two 2 until past PROGRAMMING COMPLETE PRESS SETTINGS KEY 3 SEC TO UNLOCK 1 The display may read PRESS SETTINGS KEY Press button one 1 for three seconds 3 to unlock 2 After three 3 seconds t...

Page 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Page 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Page 28: ...tions happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring th...

Page 29: ...of the holder and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the ResCare bottle on the...

Page 30: ...oz ResCare SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the softene...

Page 31: ...l and repeat until finishing with a seal Important use the specialized end spacer and note it s placement 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston...

Page 32: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Page 33: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Page 34: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Page 35: ...be running at the drain 1 Replace the motor and transformer if unable to determine the output of the transformer separately 2 Contact your authorized installer for parts and or assistance COMMON SPAR...

Page 36: ...any force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of this w...