9. Specifications
.71.
.70.
Dimensions (W*H*D)
Weight
1178*713.5*315 (mm) / 46.3*28.1*12.4 (inch)
84kg / 185.2lb
3/PE~600
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
MPPT efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Noise emission
Cooling concept
Max.operation altitude
AC connection
Compliance
DC connection
1500
150
300
1/20
0.8leading~0.8lagging
60
99.1%
98.6%
99.9%
Transformerless
<
3W (without anti-PID)
-
25
℃...
+60
℃
0~100%
NEMA4X/IP65
≤
65dB(A)
Fan cooling
4000m
Display
OTA update
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4
OT Terminal connectors
(
Max.185mm²
)
LCD
Yes
RS485/Ethernet
10 years standard (extend to 20 years)
950
125000
125000
125000
120
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
860...1450
900
UL 1741, UL 1741SA, Rule 21, UL 1998,
UL 1699B, IEEE 1547,FCC Part 15 (Class A & B),
CAN/CSA C22.2 107.1-1,Rule 21 Phaes II&III
CSI-125KTL-GS-E
8. Troubleshooting
Alarms
Cause
Solution
• Inverter detects grid
instability, internal fault
current high
GRID-INTF:
Grid unstable
Test – With DC Switch OFF
• Measure AC voltage
• Test AC line for THD
• Test – With DC Switch ON
Test AC line for THD
• Multiple inverters/turn one off
• Impedance matching adjustment or box
• Internal damage
• Wire came loose in shipping
INI-PRO:
Initialization
Protection
• Master and Slave DSP
have different values
Reset Inverter
• DC switch OFF
• Wait until all lights/LCD turn off
• DC switch ON
• Replace inverter
TEM-PRO:
Temperature
Protection
• Inverter detects high
ambient temperature >60C
Inspect installation
• Check heatsink for obstructions/ventilation
• Is inverter in direct sunshine
• Measure ambient temperature near inverter
• If temp is in range replace inverter
GROUND-PRO:
Ground
Protection
• Inverter detects low DC
insulation resistance
Inspect installation
• Reset inverter
• Note weather conditions when alarm occurs
• Measure insulation resistance
• If normal, measure in SAME weather as alarm
• Physically check cables
• Replace inverter
Table 8.1 Fault messages and descriptions
Screen OFF
with DC applied
• Inverter internally
damaged
• Do not turn off the DC switches as it may
damage the inverter.
Please wait for sunset and confirm the string
•
current is less than 0.5A with a clip-on ammeter
and then turn off the DC switch. String current
above 0.5A is under load.
• Note: Damage due to wrong connections or fire
caused by removing string wires or opening
fuse holders under load is not covered in the
device warranty.