Model Type 

Maximum 

power 

Operating 

voltage 

Operating 

current 

Open Circuit 

Voltage 

Short Circuit 

Current 

Max. Series 

Fuse Rating 

Overall Dimension 

<mm> 

Weight 

<Kg> 

Pmax <W> 

Vmp <V> 

Imp <A> 

Voc <V> 

Isc <A> 

<A> 

CS6AH-235M

 

235 

 

24.5 

 

9.60 

 

29.0 

 

10.21 

 

20 

 

CS6PH-240P

 

240 

 

28.2 

 

8.52 

 

33.8 

 

9.41 

 

20 

 

1638×982×40 

1638×982×35 

 

19.00 

CS6PH-245P

 

245 

 

28.4 

 

8.63 

 

34.0 

 

9.48 

 

20 

 

CS6PH-250P

 

250 

 

28.6 

 

8.75 

 

34.2 

 

9.55 

 

20 

 

CS6PH-255P

 

255 

 

28.8 

 

8.86 

 

34.4 

 

9.62 

 

20 

 

CS6PH-260P

 

260 

 

29.0 

 

8.97 

 

34.6 

 

9.69 

 

20 

 

CS6PH-265P

 

265 

 

29.2 

 

9.08 

 

34.8 

 

9.76 

 

20 

 

CS6PH-270P

 

270 

 

29.4 

 

9.19 

 

35.0 

 

9.83 

 

20 

 

CS6PH-275P

 

275 

 

29.6 

 

9.30 

 

35.2 

 

9.90 

 

20 

 

CS6PH-280P

 

280 

 

29.8 

 

9.40 

 

35.4 

 

9.97 

 

20 

 

CS6PH-280M

 

280 

 

30.0 

 

9.34 

 

36.5 

 

9.96 

 

20 

 

1638×982×40 

1638×982×35 

19.00 

CS6PH-285M

 

285 

 

30.3 

 

9.41 

 

36.7 

 

10.02 

 

20 

 

CS6PH-290M

 

290 

 

30.6 

 

9.48 

 

36.9 

 

10.08 

 

20 

 

CS6PH-295M

 

295 

 

30.9 

 

9.55 

 

37.1 

 

10.14 

 

20 

 

CS6PH-300M

 

300 

 

31.2 

 

9.62 

 

37.3 

 

10.19 

 

20 

 

CS6PH-305M

 

305 

 

31.5 

 

9.69 

 

37.5 

 

10.25 

 

20 

 

CS6PH-310M

 

310 

 

31.8 

 

9.75 

 

37.7 

 

10.31 

 

20 

 

CS6XH-345M

 

345 

 

36.5 

 

9.46 

 

44.4 

 

9.94 

 

20 

 

1954×982×40

 

1954×982×35 

23.00 

CS6XH-350M

 

350 

 

36.8 

 

9.52 

 

44.6 

 

10.00 

 

20 

 

CS6XH-355M

 

355 

 

37.1 

 

9.57 

 

44.8 

 

10.06 

 

20 

 

CS6XH-360M

 

360 

 

37.4 

 

9.63 

 

45.0 

 

10.12 

 

20 

 

CS6XH-365M

 

365 

 

37.7 

 

9.69 

 

45.2 

 

10.18 

 

20 

 

CS6XH-370M

 

370 

 

38.0 

 

9.74 

 

45.4 

 

10.24 

 

20 

 

CS6XH-375M

 

375 

 

38.3 

 

9.80 

 

45.6 

 

10.30 

 

20 

 

CS6XH-295P

 

295 

 

34.4 

 

8.58 

 

41.4 

 

9.52 

 

20 

 

1954×982×40

 

1954×982×35 

23.00 

CS6XH-300P

 

300 

 

34.6 

 

8.68 

 

41.6 

 

9.56 

 

20 

 

CS6XH-305P

 

305 

 

34.8 

 

8.77 

 

41.8 

 

9.60 

 

20 

 

CS6XH-310P

 

310 

 

35.0 

 

8.86 

 

42.0 

 

9.64 

 

20 

 

CS6XH-315P

 

315 

 

35.2 

 

8.95 

 

42.2 

 

9.68 

 

20 

 

CS6XH-320P

 

320 

 

35.4 

 

9.04 

 

42.4 

 

9.72 

 

20 

 

CS6XH-325P

 

325 

 

35.6 

 

9.13 

 

42.6 

 

9.76 

 

20 

 

CS6XH-330P

 

330 

 

35.8 

 

9.22 

 

42.8 

 

9.83 

 

20 

 

CS6XH-335P

 

335 

 

36.0 

 

9.31 

 

43.0 

 

9.90 

 

20 

 

CS6XH-340P

 

340 

 

36.2 

 

9.40 

 

43.2 

 

9.97 

 

20 

 

CS6XH-345P

 

345 

 

36.4 

 

9.49 

 

43.4 

 

10.04 

 

20 

 

 

The recommended maximum series fuse rating is stated in table C above.     

Summary of Contents for CS5AH-180M

Page 1: ...ABILITY 1 2 0 SAFETY PRECAUTIONS 1 3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 2 4 0 UNPACKING AND STORAGE 4 5 0 MODULE INSTALLATION 4 5 1 MODULE WIRING 7 5 2 GROUNDING 8 6 0 MOUNTING INSTRUCTIONS 8 6 1...

Page 2: ...nguage versions of this document the English version shall prevail Please refer to our product lists and documents published on our website at http www canadiansolar com as these lists are updated on...

Page 3: ...e junction box cover closed at all times Do not disassemble a module or remove any module part Do not artificially concentrate sunlight on a module Do not connect or disconnect modules when current fr...

Page 4: ...circuit voltage can be calculated using the following formula CVoc 1 Voc 25 T T is the lowest expected ambient temperature at the system installation site Voc C is the voltage temperature coefficient...

Page 5: ...n to avoid module backsheets being damaged by sharp objects as scratches may directly affect product safety Do not leave modules unsupported or unsecured Do not change the wiring of bypass diodes Keep...

Page 6: ...Temperature and humidity Please consult the Canadian Solar Inc technical support department for more information on the use of modules in special climates such as an altitude greater than 2000m Do no...

Page 7: ...en designing the system The recommended maximum series fuse rating is stated in a table in the Annex C Modules should be safely fixed to bear all expected loads including wind and snow loads A minimum...

Page 8: ...erproof when unmated When installing modules connector should be connected to each other as soon as possible or appropriate measures like using connector endcaps should be taken to avoid moisture and...

Page 9: ...less steel unless otherwise specified Canadian Solar Inc does not provide grounding hardware One grounding method is recommended for Canadian Solar Inc classic modules as described below For alternati...

Page 10: ...modules can be installed in either landscape or portrait orientations Refer to the detailed instructions for further guidance Please note that in areas with heavy snowfall 2400 Pa further countermeas...

Page 11: ...de using four standard mounting holes Mounting rails run perpendicularly to the long frame side An additional support bar should be placed below the module as shown below Maximum Load Uplift load 2400...

Page 12: ...oad 2400 Pa Downforce load 5400 Pa Compatible module types CS6XH P and CS6XH M 7 0 MAINTENANCE Do not make modifications to any component of the PV module diode junction box plug connectors or others...

Page 13: ...nadiansolar com Rev IM GN CM EN 1 0 Copyright October 2020 Canadian Solar Inc 12 performed by qualified personnel only Please refer to Annex D Module Cleaning Guide for additional information on this...

Page 14: ...as described below All the requirements of the standard module installation manual and specific tracker detailed installation instructions should apply Tracker 1P Clamping method Overlap support lengt...

Page 15: ...10 41 6 5 07 49 4 5 38 15 CS5PH 235P 235 50 8 4 63 62 6 4 93 15 1602 1061 40 1602 1061 35 20 30 CS5PH 240P 240 51 0 4 71 62 8 5 00 15 CS5PH 245P 245 51 4 4 79 63 0 5 07 15 CS5PH 250P 250 51 4 4 87 63...

Page 16: ...290 30 6 9 48 36 9 10 08 20 CS6PH 295M 295 30 9 9 55 37 1 10 14 20 CS6PH 300M 300 31 2 9 62 37 3 10 19 20 CS6PH 305M 305 31 5 9 69 37 5 10 25 20 CS6PH 310M 310 31 8 9 75 37 7 10 31 20 CS6XH 345M 345...

Page 17: ...t in injury Ensure that the array has been disconnected to other active components such as inverter or combiner boxes before starting with the cleaning Wear suitable protection clothes insulated glove...

Page 18: ...be applied as long as the method is efficient enough considering the existing conditions Method B Wet cleaning If excessive soiling is present on the module surface a non conductive brush sponge or o...

Reviews: