Installation: Electrical power requirements
Single Phase 3 wires (live, neutral, ground)
230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)
For Single Phase connection (1 x 32A):
1. Put DIP switch A2 on ON and DIP switch A5 on OFF
Power connections
Single Phase (A)
is the normal wiring configuration for most household electrical installations (3 wires: live, neutral and earth). If however you
have insufficient Amps you will need to use other connection (see below).
2 Single Phase connection (B)
is used in circumstances where the
power supply is limited and where you need more Amps.
3 Phase (C)
is used in certain areas of Europe where 3 Phase power is available and
the installation warrants it.
NOTE:
Canadian Spa Company requires that the electrical installation of your hot tub is carried out by a
professionally licensed electrician and that all local electrical and building codes are adhered to.
A.) Single Phase connection (Most common):
NBP6013H Circuit Board
Toronto & Toronto SE