Any time you change a DIP Switch, other than A1, you
must reset Persistent Memory for your new DIP Switch
Settings changes to take effect. If you do not reset Persis
-
tent Memory, your system may function improperly.
To reset Persistent Memory:
• Power down by disconnecting power source from spa.
• Put a jumper across J43, covering both pins.
• Power up by connecting power source to spa.
• Wait until “
Pr
” is displayed on your panel.
• Power down again.
• Remove jumper from J43
(May also move to cover 1 pin only)
• Power up again.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to
store a variety of settings. What we refer to as Persistent
Memory stores the filter settings, the set temperature, and
the heat mode.
DIP Switch Functions
Fixed-function DIP Switches
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump
(or blower) with Heater.
A3
In “ON” position, add two high-speed pump
(or 1 HS Pump and Blower) with Heater.
A5
In “ON” position, enables Special Amperage
Rule B. See Special Features section under
Configuration Options for functionality with
your system. In “OFF” position, enables Special
Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering
up to restore factory settings as determined by software
configuration).
A2 and A3
work in combination to determine the number of
high-speed devices and blowers that can run before
the heat is disabled. i.e. A2 and A3 in the ON position will
allow the heater to operate with up to 3 high-speed pumps
(or two HS Pumps and Blower) running at the same time.
Heat is disabled when the fourth high-speed pump or
blower is turned on.
Note: A2/A3 all off = No heat with any
high-speed pump or blower.
Assignable DIP Switches
A4
In “ON” position, enables a 5-minute cooldown for some
gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cooldown for electric
heaters (Cooling Time A).
A7
In “ON” position, Simplified Menus on TP400/TP500/TP600.
Do not use graphic panels (TP800, TP900, or spaTouch™
family) with Simplified Menus.
In “OFF” position, Regular Menus on TP400/TP500/TP600.
This setting is compatible with all panels.
Undesignated switches are not assigned a function.
Jumper Definitions
J109
Non Applicable on CE models
J30
Do Not Use
J31
Jumper on 1 pin with 2.0kW or smaller heater
Jumper on 2 pins with a 3.0kW or higher heater.
NOTE: Jumper setting varies by system model
which is shown to the right of the jumper.
J44
Jumper must be on center two pins (240V) for CE
Systems.
WARNING:
Setting DIP switches or jumpers incorrectly may cause abnormal
system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct
settings for this system.