background image

O K A N A G A N / S A S K A T O O N / G A N D E R / M U S K O K A   S P A S

Reminder Messages

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 90 da

ys.

Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions.

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 180 days.

Vinyl covers should be cleaned and conditioned for maximum life.

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 180 days.

Wood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life.

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 365 days.
Filters should be replaced occasionally to maintain proper spa function and sanitary conditions.

 

 

 

 

Alternates with temperature or normal display.

As needed. Install new mineral cartridge.

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 365 days.

Check your ozone and/or UV generator per your spa manufacture’s instructions.

 

 

 

 

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 365 days.

Have a service technician do a check-up on your spa per your spa manufacturer’s instructions.

(24)

Summary of Contents for BP Series

Page 1: ...S A S K AT O O N G A N D E R M U S K O K A S PA S Patio Spas Owners Manual BP Series canadianspacompany com For Service Support please contact us anytime support canadianspacompany com Okanagan Saskatoon Gander Muskoka ...

Page 2: ... questions Submit a ticket in our system and our global team will effectively solve your issue quickly and efficiently 24 7 BACK GARDEN DELIVERY FORM Take your smart phone and tape measure outside with you and attach information directly from your phone At your convenience upload your information to our site and our experienced delivery team will organise your delivery and installation 2 https www...

Page 3: ...ocution Do not connect any auxiliary components for example cable additional speakers headphones additional audio video components etc to system 11 CAUTION Risk of Electrical Shock Do not service this product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury Refer all servicing to qualified service personnel 12 CAUTION Risk of Electrical Shock...

Page 4: ...be certain restrictions and or requirements that are particular to your locality If in doubt check with your local council Installation and Ground surface requirements Ground preparation is not included in the sale of any spa or gazebo The location where you are planning to put your spa and or gazebo must be completely prepared The site must be smooth flat and level to ensure complete contact with...

Page 5: ...time to drop off your spa OPTION 2 Buyer collects hot tub using own transport from one of our warehouses Please arrange 48 hours prior to collection Monday Friday 10 am 4pm OPTION 1 Delivery from warehouse and delivered to customer and moved into hot tub location Customer to provide access for position see our guide for measurements required for each spa OPTION 2 Delivery from warehouse to custome...

Page 6: ...r clean water source directly into filter housing Push hose pipe into filter housing until it stops Fill up to middle of the skimmer Secure hose placement and turn on water Filling the spa through the filter housing prevents an air lock from occurring in the spa pump which is an air pocket preventing the flow of water through the pump Permanent damage caused by running the pump with an air lock or...

Page 7: ... does not change with the dosing of the granules Check the pH value using the 3 function test strips at least once a week and if necessary adjust it to 7 2 7 6 Add 10 g m of Chlorine granules after each bathing session Let the circulation pump run for 10 minutes and then check afterwards using 3 function test strips that the ideal value of 1 0 1 5 ppm mg L is reached If necessary continue to dose ...

Page 8: ...ntaminants combined chlorine Chlorine level too high A pH too low B combined chlorine due to high concentration of organic contaminants A high concentration of organic contaminants using up sanitizers B test trips may be ineffective SOLUTION A shock treatment with Granular Chlorine B add Granular Chlorine use SPA BALL C add pH DOWN until pH level reads 7 2 7 6 D add pH DOWN adjust total alkalinity...

Page 9: ...re is done with 2 or 3 buttons on the control panel Some panels have separate WARM Up and COOL Down buttons while others have a single Temperature button In the navigation diagrams Temperature buttons are indicated by a single button icon Panels that have two Temperature buttons Warm and Cool can use both of them to simplify navigation and programming where a single Temperature icon is shown The M...

Page 10: ...peed and then again to switch to high speed will now be running in high speed to facilitate priming If the pump has not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pump to continue to run Turn off the pump and repeat the process Note Turning the power off and back on again will initiate a new pump priming session Sometimes momentarily turning the pump ...

Page 11: ...er cycle can be enabled as needed At the start of each filter cycle all water devices other than the primary pump will run briefly to purge the plumbing to maintain good water quality Freeze Protection If the temperature sensors within the heater detect a low enough temperature then the pump automatically activate to provide freeze protection The pump will run either continuously or periodically d...

Page 12: ...emperature is flashing the temperature will continue to change until the button is released If only one temperature button is available and the limit of the Temperature Range is reached when the button is being held the progression will reverse direction Dual Temperature Ranges This system incorporates two temperature range settings with independent set temperatures The High Range designated in th...

Page 13: ...l only allow heating during programmed filter cycles Since polling does not occur the temperature display may not show a current temperature until the primary pump has been running for a minute or two In Rest Mode the spa will only heat to set temperature during programmed filter times even though the water is being filtered constantly when in Circulation Mode Ready in Rest Mode appears in the dis...

Page 14: ...e of Day when powered down If power is interrupted to such a system Time of Day is not stored The system will still operate and all other user settings will be stored If filter cycles are required to run at a particular time of day resetting the clock will return the filter times to the actual programmed periods When such a system starts up it defaults to 12 00 Noon so another way to get filter ti...

Page 15: ...llows access to a reduced selection of menu items These include Set Temperature FLIP LOCK UTIL INFO and FALT LOG Light Timer Programming Light Timer Option If LITE TIMR does not appear in the Main Menu the Light Timer feature is not enabled by the manufacturer When available the Light Timer is OFF by default Unlocking This Unlock sequence may be used from any screen that may be displayed on a rest...

Page 16: ...is programmed to begin Adjusting Filtration Main Filtration Filter cycles are set using a start time and a duration Start time is indicated by an A or P in the bottom right corner of the display Duration has no A or P indication Each setting can be adjusted in 15 minute increments The panel calculates the end time and displays it automatically Hold Mode MO37 Hold Mode is used to disable the pump d...

Page 17: ...ay RE MIN DERS Reminders Turn the display of reminder messages like Clean Filter On or Off Note Reminders continue to run in the background even when not displayed So turning the display of Reminders On or Off does not reset any Reminder counts CLN UP Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run after each use...

Page 18: ...INFO The Utilities Menu contains the following A B A B Sensor Temperatures When this is set to On the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater FALT LOG Fault Log The Fault Log is a record of the last 24 faults that can be reviewed by a service tech RCD 18 ...

Page 19: ...Too Cold Freeze Protection A potential freeze condition has been detected or the Aux Freeze Switch has closed and the pump is activated depending on how your system was built The pump is ON for at least 4 minutes after the potential freeze condition has ended or when the aux freeze switch opens In some cases the pump may turn on and off and the heater may operate during Freeze Protection This is a...

Page 20: ...heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater start up See Flow Related Checks below Heater is too Hot OHH MO30 One of the water temp sensors has detected 118 f 47 8 C in the heater and the spa is shut down You must pr...

Page 21: ...for at least 1 hour Call for Service Sensor Failure Sensor A MO31 Sensor B MO32 A temperature sensor or sensor circuit has failed Call for Service Miscellaneous Messages No Communications The control panel is not receiving communication from the System Call for Service Pre Production Software The Control System is operating with test software Call for Service F or C is replaced by T The Control Sy...

Page 22: ...r dealer or service organization Configuration Error Spa will not Start Up Contact your dealer or service organization GFCI Failure System Could Not Test Trip the GFCI MO36 NORTH AMERICA ONLY May indicate an unsafe installation Contact your dealer or service organization This message can be reset from the topside panel with any button press Sensor Related Messages A Pump Appears to be Stuck ON MO3...

Page 23: ...pears on a regular schedule e g every 7 days Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals Alternates with temperature or normal display Appears on a regular schedule e g every 30 days Clean the filter media as instructed by the manufacturer See HOLD on page 9 Alternates with temperature or normal display Appears on a regular schedule e g...

Page 24: ...irting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life Alternates with temperature or normal display Appears on a regular schedule e g every 365 days Filters should be replaced occasionally to maintain proper spa function and sanitary conditions Alternates with temperature or normal display As needed Install new mineral cartridge Alternates with ...

Page 25: ...O K A N A G A N S A S K AT O O N G A N D E R M U S K O K A S PA S 25 BP550 Topside ...

Page 26: ...o restore factory settings as determined by software configuration A2 and A3 work in combination to determine the number of high speed devices and blowers that can run before the heat is disabled i e A2 and A3 in the ON position will allow the heater to operate with up to 3 high speed pumps or two HS Pumps and Blower running at the same time Heat is disabled when the fourth high speed pump or blow...

Page 27: ...intain water chemistry in accordance with the Manufacturers instructions Warning The equipment and controls shall be located not less than 1 5 metres horizontally from the spa or hot tub Warning RCD Protection The Owner should test and reset the RCD on a regular basis to verify its function Warning Shock Hazard No User Serviceable Parts Do not attempt service of this control system Contact yourdea...

Page 28: ...ther conditions regular maintenance or protection is essential Canadian Spa Co warrants the cover for the period of one 1 year Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIMITATIONS Any defect or damage caused by installation alteration or repair by anyone who is not an employee of Canadian Spa Co or authorised service technician is not cover...

Reviews: