4
requirements of the authority having jurisdiction or, in the
absence of such requirements, with national electrical code,
ANSI/NFPA70 and/or the Canadian electrical code part 1
CSA C22.1. Where required by the authority having
jurisdiction, the installation must conform to American
Society of Mechanical Engineers Safety Code for Controls
and Safety Devices for Automatically Fired Boilers, ASME
CSD-1. All boilers conform to the latest edition of the
ASME Boiler and Pressure Vessel Code, Section II. Where
required by the authority having jurisdiction, the installation
must comply with the CSA International, CAN/CGA-B149
and/or local codes. This appliance meets the safe lighting
performance criteria with the gas manifold and control
assembly provided, as specified in the ANSI standards for
gas-fired units, ANSI Z21.13.
1.7 WARRANTY
•
Factory warranty (shipped with unit) does not
apply to units improperly installed or improperly
operated.
•
Factory warranty shall apply only when the
appliance is installed in accordance with local
plumbing and building codes, ordinances and
regulations, the printed instructions provided with it
and good industry practices.
•
Excessive
water hardness
causing a lime build-
up in the copper coils or tubes is not a fault of the
appliance and is not covered by warranty. Consult
the factory for recommendations for use in hard
water areas.
(See Water Treatment and Water
Chemistry)
•
Excessive pitting and erosion on the inside of the
copper tube may be caused by too much
water
velocity
through the tubes and is not covered by
the manufacturer’s warranty (See Boiler Flow
Rates and Temperature Rise for flow
requirements).
•
Using or storing
corrosive chemicals
in the
vicinity of this appliance can rapidly attack the
copper tubes and coils and voids warranty.
•
In case of
Condensing
or
Non-Condensing
DynaFlame
, The Main (Primary) Heat Exchanger
is intended to operate under non-condensing
conditions.
Inlet water temperatures
must be
maintained at 110°F (64°C) or higher. Warranty is
void if the Primary heat exchanger is allowed to
operate in condensing mode.
•
Damage caused by
freezing or dry firing
voids
warranty.
•
This appliance is not to be used for
temporary
heating
of buildings under construction.
•
The manufacturer shall
NOT
be held liable for any
personal injury or property damage due to ice
formation or the dislodging of ice from the vent
system or the vent termination
1.8
REMOVAL OF EXISTING APPLIANCE
When an existing appliance is removed from a common
venting system, the common venting system is likely to be
too large for proper venting of the appliances remaining
connected to it .At the time of removal of an existing
appliance, the following steps must be followed with each
appliance remaining connected to the common venting
system placed in operation, while the other appliances
remaining connected to the common venting system are
not in operation.
•
Seal any unused openings in the common venting
system.
•
Visually inspect the venting system for proper size
and horizontal pitch and determine that there is no
blockage, restriction, leakage, corrosion or other
deficiency, which could cause an unsafe condition.
•
Insofar as is practical, close all building doors and
windows and all doors between the spaces in
which the appliances remaining connected to the
common venting system are located and other
spaces of the building. If applicable turn on the
clothes dryers and any appliances not connected
to the common venting system. Turn on any
exhaust fans, such as range hoods and bathroom
exhausts, so they will operate at maximum speed.
Do not operate a summer exhaust fan. Close
fireplace dampers.
•
Place in operation the appliance being inspected.
Follow the lighting instructions. Adjust thermostat
so that appliance operates continuously.
•
If provided, test for spillage at the barometric
damper relief opening after 5 minutes of main
burner operation. Use a cold mirror, the flame of a
match, or candle or smoke from a cigarette.
•
After it has been determined that each appliance
remaining connected to the common venting
system properly vents when tested as outlined
above, return doors, windows, exhaust fans,
fireplace dampers and any other gas-burning
appliance to their previous condition of use.
•
Any improper operation of the common venting
system should be corrected so that the installation
conforms to the National Fuel Gas Code, ANSI
Z223.1 and/or CAN/CGA B149, Installation Codes.
When resizing any portion of the common venting
system, the common venting system should be
resized to approach the minimum size as
determined using the appropriate tables in Part 11
of the National Fuel Gas Code, ANSI Z223.1 and
/or CAN/CGA B149, Installation Codes.
Heat exchanger surfaces and vent piping should be
checked every six months for deterioration and carbon
deposits. Remove all soot or other obstructions from the
chimney and flue, which might impede draft action. Replace
any damaged or deteriorated parts of the venting system.
A qualified service technician should follow this procedure
when inspecting and cleaning the heat exchanger and vent
pipe.
1. Turn off electrical power and main manual gas shut-off
and allow appliance to cool down.
2. Remove the vent pipe running to the chimney and
check heat exchanger, vent and chimney for
obstruction and clean as necessary.
3. Remove burner from appliance and carefully clean as
required. Never brush or wipe the knitted metal fibber
surface, use a garden hose and wash instead.
Caution: Never use pressure washer to clean the
burner.
4. Use pressure wash to clean heat exchanger if
necessary.
5. Reinstall parts removed in steps 2 and 3. Be sure that
vent pipe has proper pitch and is properly sealed.
Summary of Contents for DFH500
Page 31: ...28 PART 9 TROUBLE SHOOTING ...
Page 32: ...29 ...
Page 39: ...36 PART 12 EXPLODED VIEW ...
Page 40: ...37 ...
Page 41: ...38 ...
Page 46: ...43 PART 13 ELECTRICAL DIAGRAMS ...
Page 47: ...44 ...
Page 48: ...45 ...
Page 49: ...46 ...
Page 50: ...47 ...
Page 51: ...48 ...