background image

Powerbox Australia Pty Ltd

Powerbox Pacific Ltd

4 Beaumont Rd Mount Kuring Gai NSW 2080 AUSTRALIA

1800 251 380  [email protected]   

www.powerbox.com.au

 

1a Henry Rose Place Albany Auckland 0632 NEW ZEALAND

09 4158 320   [email protected]    

www.powerbox.co.nz

 

Sydney

 (Head Office) 

Auckland 

(Subject to alterations.  This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)

Version 1.0  10/2018

8

 

 

Camtec Power Supplies GmbH – Gewerbestrasse 30 – D-76327 Pfinztal – Germany        

p.8/8 (12.2017.02.0)

 

Phone +49(721)46596-0  -  Fax +49(721)46596-77 – 

www.camtec-gmbh.com

 - 

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

 
 

Ordering Information 

Output  

Type (DIN-Rail standard)  Part Number 

Remarks 

0-15V 

HSEUreg10001.015T 

3041053001CA 

 

0-30V 

HSEUreg10001.030T 

3041053002CA 

 

0-50V 

HSEUreg10001.050T 

3041053003CA 

 

0-90V 

HSEUreg10001.090T 

3041053004CA 

 

0-130V 

HSEUreg10001.130T 

3041053005CA 

 

0-180V 

HSEUreg10001.180T 

3041053006CA 

 

Option 

Screw Terminal Plug 

3520037 for the pack 

Optional Plug for the interface, 2 poles LS5,08 180°cabling, (10pcs each pack) 

Option 

ADTW201 

3041090001CA 

Optional DC-repeater 1:1 with no losses for save interface separation >60Vdc 

Option 

Protective Coating 

Ask for technical support and personal quote from your retailer 

 
 
 

Safety regulations: Please read these instructions completely before using the equipment. Keep these instructions on to hand. 
The device may only be operated by trained specialist staff. 

 
Installation: 

1) The device is designed for devices and systems 
that meet the standard requirements for hazardous 
voltages, power and fire prevention. 
2.) Installation and service only by trained persons. 
The AC power must be switched off. The work is to be 
labeled; accidental reconnection of the system must 
be prevented. 
3.) Opening the device, its modification, loosening 
bolts or operation outside the specified herein 
specification or in an unsuitable environment, has the 
immediate loss of warranty to follow. We disclaim any 
responsibility for any resulting damage to persons or 
things. 
4.) Note: The device must not be operated without an 
upstream circuit breaker (CB). We recommend the use 
of C-Type 16A. It is prohibited to use the unit without 
PE. It may be necessary upstream device has a power 
switch. 

 
Warning: 
Non-compliance can result in fire and serious injury or death. 

1. Operate the appliance without PE connection. 
2. Before connecting the device to the AC network, 
make wires free of voltage and assure accidently 
switch on. 
3. 

Allow neat and professional cabling

4. Never open nor try to repair the unit. Inside are 
dangerous voltages that can acause electrical shock 
hazard. 
5. Avoid metal pieces or other cunductive material to 
fall into the item

 

6. Do not operate the device in damp or wet 
conditions 
7. Do not operate the unit under EX-conditions 

 

All parameters base on 15 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated. 

Summary of Contents for HSEUREG10001 Series

Page 1: ... Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death HSEUREG10001 1000W Programmable DC Lab Power Supply TS35mm DIN Rail Specification Save 0 Umax programming Multi interface 0 10V 0 20mA Sense Shutdown remote ON OFF N 1 parallel operation Natural Convection Precise dynamic resp...

Page 2: ... interface are electrically isolated The design specifications call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of IEC CSA UL60950 1 and the EMC standards EN55022 Class B The 480W and 720W models provide natural convection The 1kW models use a forced air cooling system with a two stages fan In selecting the fan as wi...

Page 3: ...z 50mVpp 50mVpp 100mVpp 200mVpp 250mVpp 300mVpp Sense function Compensation 2V per lead load protective electrical separation 60Vdc Remote Shutdown protective electrical separation 60Vdc Analogue Interface see table protective electrical separation 60Vdc working impedance 500Ω Pmax average 1000W continuous and ca 1059 1118W bower boost for max 60s see Power Boost above Derating 60 C 70 C 2 5 C Acc...

Page 4: ...31 3 1 60 6 0 Output Capacity mF typ 8 56 8 56 1 52 0 54 0 23 0 23 Interface Latency 15ms including signal latency for 0 Umax programming Analog Interface Pin Name Type Function Signal Remarks 1 Ureg Input Voltage Programming 0 10Vdc 20mA 0 20mA multi functional interface 500 Ω working resistance with voltage programming 2 Ureg Input 3 Sense Input Sense Control none Compensation max 2V per load li...

Page 5: ...the power supply controls the DC power directly to the DC output terminals In case of an error the OVP acts automatically see OVP values corresponding technical table page 3 The sense terminals are directly connected to the power outputs Remote Sensing Schematics Although the HSEUREG sense block is more simple it applies to the below schematics Please note that the HSEUREG has no AUX connection fe...

Page 6: ...ve 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Parallel Operation N 1 Decoupling In order to increase the overall power of the power supply two or more devices of the same model with the same output voltage may be operated in parallel We recommend using a busbar for the DC power connector Make sure that the cable leng...

Page 7: ...eld test owner test follow the below instruction a Use suitable test equipment raising the voltage slowly b Short circuit L1 and N and all the DC output terminals c Use only test voltages of 50 60Hz The outputs are unearthed and therefore they have no resistance to GND PE d If the residual voltage is 60Vdc observe the safety standards Use only specially insulated screwdriver to trim the Ua Ia Term...

Page 8: ...m your retailer Safety regulations Please read these instructions completely before using the equipment Keep these instructions on to hand The device may only be operated by trained specialist staff Installation 1 The device is designed for devices and systems that meet the standard requirements for hazardous voltages power and fire prevention 2 Installation and service only by trained persons The...