CPS-EC1000(R2) MANUAL
Camtec Power Supplies GmbH - Gewerbestrasse 30 - 76327 Pfinztal - Germany
P.4/12 (03.2022.00.0)
Phone +49(721)46596-0 - Fax +49(721)46596-77 -
www.camtec-gmbh.com
-
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Manual and Technical Details
1) Active Transient Filter 2) Rectifier 3) Inrush Current Limiter 4) Load Capacitor 5) Power Transformer 6) Storage Choke
LED: CV = constant voltage operation CC = constant current operation SD/INH = shutdown / inhibit OT = temperature failure >70°C
Technical Data Table - Analogue Interface & Voltage Current Control
Feature
Technology
Details and Connections
Section
Isolation
Potentiometer Voltage
15 turns
High precision
U adj
3000Vac to input & output
Potentiometer Current
15 turns
High precision
I adj
3000Vac to input & output
Monitoring Current
0...5Vdc/5mA
AWG22 – AWG6 / 0,25 – 2,5mm²
I mon
3000Vac to input
Shutdown
Open Collector
AWG22 – AWG6 / 0,25 – 2,5mm²
SD
3000Vac to input & output
Inhibit (Interlock)
Passive
AWG22 – AWG6 / 0,25 – 2,5mm²
Inhibit
3000Vac to input & output
Sense Compensation
1V per load line
AWG22 – AWG6 / 0,25 – 2,5mm²
Sense & Aux
3000Vac to input
Power Good Relay
“b” contact
AWG22 – AWG6 / 0,25 – 2,5mm²
DC-OK
3000Vac to input & output
All potentiometers and all the inputs and the outputs of the analogue interface provide a forced isolation. It is to
ensure a protective isolation for the 300Vdc.
DC Voltage & Current adjustment range
Rated DC Voltage
24Vdc
36Vdc
48Vdc
60Vdc
72Vdc
110Vdc
150Vdc
220Vdc
300Vdc
Rated DC Current
42A
28A
21A
16,7A
13,9A
9,1A
6,7A
4,55A
3,33A
DC Voltage Setting Range
24 –
30Vdc
36 –
45Vdc
48 –
58Vdc
60 –
75Vdc
72 –
90Vdc
110 –
137,5Vdc
132 –
180Vdc
220 –
264Vdc
264 –
360Vdc
DC Current Setting Range
21 –
44,1A
14 –
29,4A
10,5 –
22A
8,0 –
17,6A
7,0 –
14,6A
4,6 –
9,6A
3,4 –
7,0A
2,3 –
4,8A
1,7 –
3,5A
The DC voltage and the current can be adjusted with a high precision 15 turn potentiometer with low
temperature fading. The factory setting is to the rated voltage & current from the table above. Due to the
tolerances of the potentiometers, the lower margin of the output voltage can be adjusted below the upper
threshold margin of the DC Power Good Relay (see p.6). To ensure a proper operation, the DC voltage setting
must stay above the upper hysteresis level of the Power Good Relay. We guarantee the above given
adjustment ranges with a tolerance of -5/0% for the lower margin and 0/+5% for the upper margin.