 A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed  storage area, such as a 
closet, unless there is adequate circulation of air in and out of the area.

Positioning the unit

 Do not use outdoors.
 This dehumidifer is intended for indoor residential 
 applications only. This dehumidifier should not be used
 for commercial or industrial applications.
 Place the dehumidifier on a smooth, level floor strong
 enough to support the unit with a full bucket of water.
 Allow at least 20cm of air space on all sides of the unit
 for good air circulation.
 Place the unit in an area where the temperature will not
 fall below 5 C(41 F). The coils can become covered with 
 frost at temperatures below 5 C(41 F), which may reduce
 performance.
 Place the unit away from the clothes dryer, heater or radiator.
 Use the unit to prevent moisture damage anywhere books
 or valuables are stored.
 Use the dehumidifier in a basement to help prevent 
  moisture damage.
 The dehumidifier must be operated in an enclosed
 area to be most effective.
 Close all doors, windows and other outside openings
 to the room.

When using the unit

 When first using the dehumidifier, operate the unit continuously 24 hours.

O

O

O

O

This unit is designed to operate with a working environment between 5C(41 F) and 35 C(95 F).
If the unit has been switched off and needs to be switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other electrical appliances.
Select a suitable location, making sure you have easy access to an electrical outlet.
Plug the unit into an electrical socket-outlet with earth connection.
Make sure the Water bucket is correctly fitted otherwise the unit will not operate properly.

OPERATING THE UNIT

20cm or more

20cm or more

20cm or more

20cm or more

40cm or 
more

Fig.4

Casters(Install at four points on the bottom 
of unit)
    

Casters can only move laterally.

    Do not force casters to move over carpet, 
    nor move the unit with water in the bucket.
    (The unit may tip over and spill water.)
NOTE:Casters is optional,some models without.

OPERATING THE UNIT

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket
    with even strength, and pull it 
    out from the unit.

3. Pour the water out.

    

When the bucket is full, the unit will automatically stop 

     running and display  P2  , the Full indicator light will flash. 
     Slowly pull out the bucket. Grip the left and right handles 
     securely, and carefully pull out straight so water does 
     not spill. Do not put the tank on the floor because the 
     bottom of the bucket is uneven. Otherwise the bucket 
     will fall down and cause the water to spill (see Fig.5 & 6).
     Throw away the water and replace the bucket. The 
      bucket must be in place and securely seated for the 
      dehumidifier to operate.
     The machine will re-start when the bucket is restored
     in its correct position.

    When you remove the bucket, do not touch any parts 
     inside of the unit. Doing so may damage the product.
     Be sure to push the bucket gently all the way into the 
     unit. Banging the bucket against anything or failing to 
     push it in securely may cause the unit not to operate. 

Fig.5

Fig.6

There are two ways to remove collected water.
1. Use the bucket

NOTES:

,,

, ,

NOTE: 

When the continuous drain feature is not being 

used,  remove the drain hose from the outlet.

2. Continuous draining

Water can be automatically emptied into a floor 
drain by attaching the unit with a water hose
(not included).

Remove the water bucket.
Cut off  the plastic cover located at drain hose 
outlet by a scissor,then insert the water hose
(ID=O13.5mm) into the drain outlet (see Fig.7) and 
securely press it onto the connector of the unit
(see Fig.8).
Lead the water hose  to the floor drain or a suitable 
drainage facility.The drainage facility should be lower 
than the drain outlet of the unit.
Make sure the connection of the water hose and the  
connector is tight and do not let the water leak.
Be sure to run the water hose sloping downward and let 
the water flow out smoothly.Do not install the water
hose as shown Fig.9a and Fig.9b.  
Replace the bucket in the unit. The bucket must be in 
place and securely seated.

 

Fig.7

Cut off the plastic
cover, then insert
the water hose.

Fig.9a

Fig.9b

Do not block water flow by a rise.

Do not block water flow by a retortion.

Water hose

Connector

Fig.8

Summary of Contents for DH20M

Page 1: ... sales agency or manufacturer for details CD009IU N3 J 2020001B0704 20120315 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CD009IU N3 J 2020001B0704 20120315 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or man...

Page 2: ...of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain When using this dehumidifier in the European countries the following information must be followed 1 1 CONTENTS SAFETY PRECAUTIONS ...

Page 3: ...cal and other technical data specific to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your unit must be used in a properly grounded wal receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a t...

Page 4: ... emptied or when the bucket is removed or not replaced in the proper position Auto Shut Off The water level control switch shuts off the dehumidifier when the bucket is full or when the bucket is removed or not replaced in the proper position When the setting humidity is reached the unit will be shut off automatically When frost builds up on the evaporator coils the compressor will cycle off and t...

Page 5: ...t may tip over and spill water NOTE Casters is optional some models without OPERATING THE UNIT Removing the collected water 1 Pull out the bucket a little 2 Hold both sides of the bucket with even strength and pull it out from the unit 3 Pour the water out When the bucket is full the unit will automatically stop running and display P2 the Full indicator light will flash Slowly pull out the bucket ...

Page 6: ...urely seated for the dehumidifier to operate Fig 9a Fig 9b After turning off the unit wait one day before emptying the tank Clean the main unit bucket and air filter Twist the excess cord onto the unit Cover the unit with a plastic bag Store the unit upright in a dry well ventilated place 4 When not using the unit for long time periods TROUBLESHOOTING TIPS Before calling for service review the cha...