background image

4

4

5

5

CONTROL PADS ON THE DEHUMIDIFIER

The control panel of the dehumidifier you 
purchased may be look like one of the following: 

MODEL A

MODEL B

Fig.2

1

1

2

2

Indicator lights(MODEL  A and MODEL B)

Power on indicator light(green)

Water full indicator light(red)

4

4

POWER Pad

This indicator light remains on(green)
 when the unit is switched on and turns 
 dark when the unit is switched off. 

Glows when the bucket is ready to be 
emptied, or when the bucket is removed 
or not replaced in the proper position.

Press to turn the unit on and off. When 
press this pad, the dehumidifier will
operate continuously for maximum 
dehumidification until the bucket is full.

Control pads(MODEL A)

Control pads(MODEL B)

5

5

POWER Pad

Press to turn the dehumidifier on and off. I

t

illuminates(green) when the unit is switched on 
and turns dark when the unit is switched off. 
When Humidity/Temperature sensor malfunction 
occurs, it blinks at 5 times per seconds.

6

6

7

7

Humidity Set Control Pads

The humidity level can be set within a range of 
35%RH(Relative Humidity) to 80%RH(Relative 
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower 
percent value(%).
For damper air, press the      pad and set  a 
higher percent value(%).

Continue  Pad

Select for the dehumidifier to operate continuously 
for maximum dehumidification until the bucket is 
full. The Humdity set control pads cannot be used 
when Continuous operation is on.Press this pad 
again to cancel Continuous operation.

3

3

Continuous operation on  indicator light
(green)-only for MODEL B

This indicator light illuminates when the 
continuous operation is on. 

1

1

4

4

2

2

1

1

2

2

3

3

5

5

6

6

7

7

8

8

IDENTIFICATION OF PARTS

Other features 

Bucket Full Light

Glows when the bucket  is ready to be emptied, or when
 the bucket is removed or not replaced in the proper position.

Auto Shut Off

The water level control switch shuts off the dehumidifier when
the bucket  is full, or when the bucket is removed or not replaced 
in the proper position. When the setting humidity is reached, the 
unit will be shut off automatically.

When frost builds up on the evaporator coils, the compressor will 
cycle off and the fan will continue to run until the frost disappears.

Auto Defrost

Identification of parts

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restarted 
opertation in the first 3 minutes. This is to protect the
unit. Operation will automatically start after 3 minutes.

Water bucket

Fig.3

Air outlet grille

8

8

Display

Shows the set % humidity level while setting, then shows the actual(

5% accuracy) room % humidity level.

Error Codes:

E1-

 Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service.

E2-

 Temperature sensor error-- Unplug the unit and plug it back in. If error repeats, call for service.

Protection Codes:

P1-

 Unit is defrosting-- Allow the unit time to automatically defrost. The error will clear after the unit self defrosts.

P2-

 Bucket is full or bucket is not in the right position-- Empty the bucket and replace in the right position.

NOTE:

 When more than one codes occur, the priority of the code display order is: 

             P2--E2--E1--P1.

Auto-Restart(on some models)

If the unit breaks off unexpectedly due to the
power cut, it will restart with the previous function
setting automatically when the power resumes.

Water level
window

Control panel

Handel

Air filter

Drain hose outlet
(see page 7)

Power Cord
and plug

Water bucket

Air outlet grille

Water level
window

Control panel

Handel

Air filter

Drain hose outlet
(see page 7)

Power Cord
and plug

MODEL I

MODEL II

NOTE:

 For MODEL A,when the temperature sensor error occurs the power indicator light  will blinks

            at 5 times per second.

Summary of Contents for DH20M

Page 1: ... sales agency or manufacturer for details CD009IU N3 J 2020001B0704 20120315 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CD009IU N3 J 2020001B0704 20120315 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or man...

Page 2: ...of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain When using this dehumidifier in the European countries the following information must be followed 1 1 CONTENTS SAFETY PRECAUTIONS ...

Page 3: ...cal and other technical data specific to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your unit must be used in a properly grounded wal receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a t...

Page 4: ... emptied or when the bucket is removed or not replaced in the proper position Auto Shut Off The water level control switch shuts off the dehumidifier when the bucket is full or when the bucket is removed or not replaced in the proper position When the setting humidity is reached the unit will be shut off automatically When frost builds up on the evaporator coils the compressor will cycle off and t...

Page 5: ...t may tip over and spill water NOTE Casters is optional some models without OPERATING THE UNIT Removing the collected water 1 Pull out the bucket a little 2 Hold both sides of the bucket with even strength and pull it out from the unit 3 Pour the water out When the bucket is full the unit will automatically stop running and display P2 the Full indicator light will flash Slowly pull out the bucket ...

Page 6: ...urely seated for the dehumidifier to operate Fig 9a Fig 9b After turning off the unit wait one day before emptying the tank Clean the main unit bucket and air filter Twist the excess cord onto the unit Cover the unit with a plastic bag Store the unit upright in a dry well ventilated place 4 When not using the unit for long time periods TROUBLESHOOTING TIPS Before calling for service review the cha...

Reviews: