background image

 

 

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE) 

6 Carson Court, Brampton, ON, CANADA, L6T 4P8 

Tel: (905) 793-2525 | Fax: (905) 793-8768 

www.campoequipment.com

  

pg. 3

 

FOREWORD  

  

This Operator's Service Manual is intended to 

familiarize  you  with  the  operation  of  and 
necessary service information for the

  

BLAZE DF2500

 gas fired model.  Please read 

this  manual  thoroughly  before  operating  the 
Blaze DF2500.  
  

This  manual  uses  the  words 

WARNING

CAUTION

,  and 

NOTE

  to  emphasize  certain 

information.   

WARNING

  identifies  personal 

safety related information; therefore, be sure to 
read  the  directive  because  it  deals  with  the 
possibility  of  personal  injury.   

CAUTION

 

identifies heater-related information; therefore, 
be sure to read the directive because it deals 
with the possibility of damaging part or parts of 
the 

Blaze 

DF2500. 

NOTE

 

identifies 

supplementary information worthy of attention.  
  

This  manual  covers  operating  instructions, 

operator  related  maintenance  instructions, 
specifications,  and  service  information.    This 
manual should be considered a permanent part 
of the Blaze DF2500 and must remain with the 
heater at the time of resale. If additional service 
information is desired, either contact your local 
dealer or write or phone:  
  

CAMPO EQUIPMENT CO.LTD. 

(ECOBLAZE)  

6 Carson Court 

Brampton, ON,  

Canada L6T 4P8  

Tel: (905)793-2525  

Fax: (905) 793-8768  

www.campoequipment.com  

 

LIMITED WARRANTY 

 

 

Campo  Equipment  CO.LTD  and  accessories 

are  warranted  to  the  original  retail  purchaser.  
No warranty is transferable to any subsequent 
owner.  The  warranty  period  is  one  year  from 
the date of purchase. The warranty covers  all 
defects in material and workmanship insofar as 
they  are  of 

Campo  Equipment  CO.  LTD

manufacture.    This  warranty  is  limited  to  the 

furnishing  of  new  parts  only,  in  the  event  the 
original  part  is  determined  to  be  defective  by 

Campo Equipment CO.LTD.

 

The warranty does not include transportation 
costs, labour for inspecting, repairing, or 
replacing original parts, or consequential 
damages.  It also does not cover any damage 
because of negligence, accident, misuse, or 
abuse.  

Campo Equipment CO.LTD

  shall not 

be liable for delays caused by defects, for 
consequential damages, or for any other 
damages, charges, or expenses of any nature.  
All parts not manufactured by 

Campo 

Equipment CO.LTD.

 are warranted insofar as 

warranted by the manufacturer of such parts.  

 

SPECIFICATIONS

  

 

 

Model Number ....................................DF2500      
Width.....................................31.50" (80.01cm) 

Length....................................... 111" (281.94 cm)

 

Height ......................................78.45"(199.26 cm)

 

Weight .........................1287.00 lbs. (583.77Kg)  

Supply panel................23.125

”x27” (Rectangular)

 

Blower Motor ............................10Hp (7.4 Kw)  

Heated Air Output.....14737 CFM (417.30 m³/min) 

Manifold Pressure” W.C….…….2.5” LP and 5.6” NG 
High  pressure  switch  to  be  adjusted  for  manifold 

pressure 

Minimum/Maximum Supply Pressure “W.C…10/14 

Pilot Pressure ......................

...............3.6” W.C 

Maximum BTU Input ........................ 2,500,000  

Kcal/h ................................................629989.4

 

   

Minimum BTU Input LP............................615938 

Kcal/h ................................................155213.8  

Minimum BTU Input NG...........................553197 

Kcal/h ................................................139403.3 
 
Required Voltage: 
208v to 240v 1Phase or 3 phase  

Full Load Amps: 
1 Phase 24 amps @ 230v 
3Phase 17 amps @230v 

This  unit  is  equipped  with  constant  voltage 
system.  It  is  activated  when  voltage  is  lower 
than 208v or higher than 235v. 
 

Minimum 4 X 420lb cylinders are to be used. 

Summary of Contents for ECOBlaze DF2500

Page 1: ...com pg 1 NG LP DIRECT FIRED SPACE HEATER BLAZE DF2500 WWW CAMPOEQUIPMENT COM REPORT 0367GH009S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CONTROLS...

Page 2: ...remain with the heater GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRE CAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE...

Page 3: ...able to any subsequent owner The warranty period is one year from the date of purchase The warranty covers all defects in material and workmanship insofar as they are of Campo Equipment CO LTD manufac...

Page 4: ...the material flash point Under no circumstance should any combustible material be stored in the airstream within 15 feet 4 57 m of the air discharge port or within 6 15 2cm of the top sides or ends of...

Page 5: ...ter Use Sherlock 5 second leak of the proper temperature or soapy water on all connections to be sure they are tight Replace or tighten any connection as necessary The supply gas hose being used must...

Page 6: ...Phase 208 to 240 V supply must be available INSTALLATION Single Phase Three Phase Up to 100 3 6 Up to 100 4 8 Up to 200 3 4 Up to 200 4 6 Up to 300 3 3 Up to 300 4 4 NOTE To power up the heater inside...

Page 7: ...re is adequate 2 Check to make sure all manual valves are open between the fuel source and the burner 3 Check to make sure the proper voltage is supplied to the heater WARNING A qualified electrician...

Page 8: ...ndent upon ambient air conditions Excessive pressure build up could occur in the supply line and lead to line failure Consult your local gas supplier for proper piping and gas codes When storing the h...

Page 9: ...ch gas can pass through the modulator The more voltage that is applied to the magnet the more gas that can pass through The modulator is typically full open when a voltage of about 24 volts DC is appl...

Page 10: ...f any mixing plates are loose or missing fasteners tighten replace as necessary Always use zinc plated or stainless fasteners 3 Observe flame pattern and if necessary take steps to correct obstructed...

Page 11: ...The following is the method for testing major electrical components WARNING A qualified electrician should perform all tests replacements and adjustments Testing the Main Switch Before assuming the C...

Page 12: ...he switch is functioning disconnect and insulate wires leading to the switch N O contacts Connect an ohmmeter or continuity light to the switch N O contacts Place the Heat Fan switch to FAN position T...

Page 13: ...s power to the VFD Burner does not ignite 1 Voltage insufficient 1 Check incoming supply 2 Electrode disconnected adjusted incorrectly defective 2 Connect adjust replace electrode 3 Air Proving Sw Dis...

Page 14: ...ctive 4 Replace Air Proving Sw 5 Flame rod dirty defective 5 Clean Replace Flame Rod 6 Inadequate fuel delivery 6 Fill Tank replace regulators valves check gas lines for obstructions TROUBLESHOOTING D...

Page 15: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 15 WIRING DIAGRAM...

Page 16: ...89 Digital Panel Mounted Voltmeter C70064 3 POSITION SWITCH C70069 FIXING COLLAR C70067 N O CONTACT BLOCK C80025 VFD C80023 R Fan C90025 Power On Indicator Light GREEN C90029 Outlet for Plug C70052 TI...

Page 17: ...C82119 2 X21 2 NIPPLE C82120 2 X90 STREET ELBOW C82121 2 X11 2 REDUCER C82122 11 2 X6 NIPPLE C82123 11 2 X90 ELBOW C82124 11 2 X2 NIPPLE C82125 2 UNION C82126 1 4 X11 2 L NIPPLE C80913 1 4 NPT x 1 4...

Page 18: ...ASSY C82191 PANEL C82192 PANEL C82193 ADAPTER PLATE C82194 R 560 FAN MOUNT ASSY C82195 CORNER STOP C82196 FAN SUPPORT BRACKET C82197 INSULATION BACK PANEL C82087 Serial Number variable data C82088 War...

Page 19: ...P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 19 C82086 E 560 FAN MOUNT ASSY C82105 15 KVA TRANSFORMER C82106 60A CONTACTORS C50242 AUXILIARY CONTACTS C82042 VSR Relay C60205 Use With...

Reviews: