background image

 

 

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE) 

6 Carson Court, Brampton, ON, CANADA, L6T 4P8 

Tel: (905) 793-2525 | Fax: (905) 793-8768 

www.campoequipment.com

  

pg. 17

 

C50131 

Black Cam Lock 

C50132 

Red Cam Lock 

C50133 

Blue Cam Lock 

C50134 

Green Cam Lock 

C82044 

CAM LOCK CAPS BLK 

C82045 

CAM LOCK CAPS RED 

C82046 

CAM LOCK CAPS BLUE 

C82047 

CAM LOCK CAPS GREEN 

C82114 

MIDCO BURNER 5FT. 

C82115 

2"X2"X3/4" TEE 

C82116 

3/4"X1/4" REDUCER  BUSH TYPE 

C82117 

2"X4" NIPPLE 

C82118 

2"X3" NIPPLE 

C82119 

2"X21/2" NIPPLE 

C82120 

2"X90° STREET ELBOW 

C82121 

2"X11/2 REDUCER 

C82122 

11/2"X6" NIPPLE 

C82123 

11/2"X90° ELBOW 

C82124 

11/2"X2" NIPPLE 

C82125 

2" UNION 

C82126 

1/4"X11/2" L NIPPLE 

C80913 

1/4" NPT x 1/4" 90 component male elbow 

C82127 

2" MAIN VALVE 

C82128 

Maxitrol Pressure Regulator 

C82129 

2" ASCO Solenoid Valve 

C60137 

1/4' Maxitrol pressure regulator 

C60129 

57.5" Copper Tubing 

C50251 

High Pressure Switch 

C70041 

RELAY 

C70042 

RELAY BASE 

C82167 

HEATER FRAME   

C82168 

PANEL    

C82169 

TOP COVER   

C82170 

Burner Shroud 2 

C82171 

Burner Shroud 1 

C82172 

BURNER SHROUD FRONT PLATE 

C82173 

PANEL    

C82174 

TRAIN DOOR   

C82175 

ELECTRIC DOOR RIGHT  

C82176 

ELEC DOOR LEFT  

Summary of Contents for ECOBlaze DF2500

Page 1: ...com pg 1 NG LP DIRECT FIRED SPACE HEATER BLAZE DF2500 WWW CAMPOEQUIPMENT COM REPORT 0367GH009S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CONTROLS...

Page 2: ...remain with the heater GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRE CAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE...

Page 3: ...able to any subsequent owner The warranty period is one year from the date of purchase The warranty covers all defects in material and workmanship insofar as they are of Campo Equipment CO LTD manufac...

Page 4: ...the material flash point Under no circumstance should any combustible material be stored in the airstream within 15 feet 4 57 m of the air discharge port or within 6 15 2cm of the top sides or ends of...

Page 5: ...ter Use Sherlock 5 second leak of the proper temperature or soapy water on all connections to be sure they are tight Replace or tighten any connection as necessary The supply gas hose being used must...

Page 6: ...Phase 208 to 240 V supply must be available INSTALLATION Single Phase Three Phase Up to 100 3 6 Up to 100 4 8 Up to 200 3 4 Up to 200 4 6 Up to 300 3 3 Up to 300 4 4 NOTE To power up the heater inside...

Page 7: ...re is adequate 2 Check to make sure all manual valves are open between the fuel source and the burner 3 Check to make sure the proper voltage is supplied to the heater WARNING A qualified electrician...

Page 8: ...ndent upon ambient air conditions Excessive pressure build up could occur in the supply line and lead to line failure Consult your local gas supplier for proper piping and gas codes When storing the h...

Page 9: ...ch gas can pass through the modulator The more voltage that is applied to the magnet the more gas that can pass through The modulator is typically full open when a voltage of about 24 volts DC is appl...

Page 10: ...f any mixing plates are loose or missing fasteners tighten replace as necessary Always use zinc plated or stainless fasteners 3 Observe flame pattern and if necessary take steps to correct obstructed...

Page 11: ...The following is the method for testing major electrical components WARNING A qualified electrician should perform all tests replacements and adjustments Testing the Main Switch Before assuming the C...

Page 12: ...he switch is functioning disconnect and insulate wires leading to the switch N O contacts Connect an ohmmeter or continuity light to the switch N O contacts Place the Heat Fan switch to FAN position T...

Page 13: ...s power to the VFD Burner does not ignite 1 Voltage insufficient 1 Check incoming supply 2 Electrode disconnected adjusted incorrectly defective 2 Connect adjust replace electrode 3 Air Proving Sw Dis...

Page 14: ...ctive 4 Replace Air Proving Sw 5 Flame rod dirty defective 5 Clean Replace Flame Rod 6 Inadequate fuel delivery 6 Fill Tank replace regulators valves check gas lines for obstructions TROUBLESHOOTING D...

Page 15: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 15 WIRING DIAGRAM...

Page 16: ...89 Digital Panel Mounted Voltmeter C70064 3 POSITION SWITCH C70069 FIXING COLLAR C70067 N O CONTACT BLOCK C80025 VFD C80023 R Fan C90025 Power On Indicator Light GREEN C90029 Outlet for Plug C70052 TI...

Page 17: ...C82119 2 X21 2 NIPPLE C82120 2 X90 STREET ELBOW C82121 2 X11 2 REDUCER C82122 11 2 X6 NIPPLE C82123 11 2 X90 ELBOW C82124 11 2 X2 NIPPLE C82125 2 UNION C82126 1 4 X11 2 L NIPPLE C80913 1 4 NPT x 1 4...

Page 18: ...ASSY C82191 PANEL C82192 PANEL C82193 ADAPTER PLATE C82194 R 560 FAN MOUNT ASSY C82195 CORNER STOP C82196 FAN SUPPORT BRACKET C82197 INSULATION BACK PANEL C82087 Serial Number variable data C82088 War...

Page 19: ...P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 19 C82086 E 560 FAN MOUNT ASSY C82105 15 KVA TRANSFORMER C82106 60A CONTACTORS C50242 AUXILIARY CONTACTS C82042 VSR Relay C60205 Use With...

Reviews: