heater.  Keep hands and feet away from any 
portion of the heater being raised.

  

 

 

WIRING

 

The  required  voltage  and  amperage  for  each 
heater is listed in the SPECIFICATIONS section 
of the manual and are also listed on the heater 
identification plate attached to the heater.  If the 
heater needs to be operated on a voltage other 
than that indicated by these decals, consult the 
factory for instructions. If a voltage change has 
been  made,  re-label  the  heater  as  such.  For 
Safety reasons, as well as preventing damage 
to the heater, NEVER leave the wrong decal in 
place.  No  information  is better  than the  wrong 
information. The heater must be wired (at every 
installation)  according  to  the  voltage  and 
amperage  required

.    A  qualified  electrician 

must 

wire 

the 

heater 

appropriately 

according  to  the  wiring  diagram  and  local, 
state, and national codes

.  

The heater must 

be electrically grounded in compliance with 
the National Electrical Code, ANSI/NFPA 70 
and  CSA  C22.1,  Canadian  Electrical  Code 
Part I.  

  
  

GAS CONNECTIONS AND 

SUPPLY 

 

 

WARNING  

Only  qualified  gas  fitting  personnel  shall 

connect  or  disconnect  fuel  supply  lines  to 
supply  tanks  and  or  gas  mains  and  the 
heater gas inlet manifold. 

 

  

All  unions  and  valves  must  be  checked  for 

tightness and proper operation before the initial 
start-up of the heater.  Use Sherlock 5-second 
leak (of the proper temperature) or soapy water 
on  all  connections  to  be  sure  they  are  tight.  
Replace  or  tighten  any  connection  as 
necessary.  
  

The  supply  gas  hose  being  used  must  be 

protected  from  traffic,  building  materials, 
and  contact  with  hot  surfaces  both  during 
usage and while in storage. 

 

 

 

The  supply  gas  hose  shall  be  visually 

inspected prior to each use of the heater.  If 
it is evident there is excessive abrasion or 
wear, or the hose is cut, it must be replaced 
prior to the heater being put into operation.   

 

 

 

The supply gas hose must be replaced with 

a  manufacture’s  authorized  replacement 
part only. 

 

 

 

See the Service Parts section of this manual 
for the appropriate replacement part.  

OPERATING GAS PRESSURES  

  

Minimum inlet pressure - 10 inches W.C (0.36 

PSI) Maximum inlet pressure 

– 14 inches W.C 

(0.50 PSI))  
  
 

OPERATING INSTRUCTIONS  

 

 

Pre-Start Checklist  

  

Before  attempting  to  start  the  Blaze  DF2500, 

several  important  checks  of  the  heater  and 
heater system are critical to safe, efficient, and 
dependable  usage.    Many  potential  problems 
can  be  avoided  by  proper  maintenance  and 
attention.  The  heater  should  be  inspected 
before  each  use,  and  at  least  annually  by  a 
qualified service personnel.  
  
1.  Familiarize  yourself  with  this  Operation  / 

Service Manual.   

2.  Check  the  entire  heater  for  any  sign  of 

physical damage.   

3.  Check for obstructions to the air intake and 

discharge of the heater.  Remove anything 
that  will  obstruct  or  restrict  airflow.    The 
heated  work  area  must  be  ventilated  to 
ensure that all air present in the workspace 
can  be  displaced  continuously  with  fresh 
heated air.  The heater air intake must be 

Summary of Contents for ECOBlaze DF2500

Page 1: ...com pg 1 NG LP DIRECT FIRED SPACE HEATER BLAZE DF2500 WWW CAMPOEQUIPMENT COM REPORT 0367GH009S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CONTROLS...

Page 2: ...remain with the heater GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRE CAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE...

Page 3: ...able to any subsequent owner The warranty period is one year from the date of purchase The warranty covers all defects in material and workmanship insofar as they are of Campo Equipment CO LTD manufac...

Page 4: ...the material flash point Under no circumstance should any combustible material be stored in the airstream within 15 feet 4 57 m of the air discharge port or within 6 15 2cm of the top sides or ends of...

Page 5: ...ter Use Sherlock 5 second leak of the proper temperature or soapy water on all connections to be sure they are tight Replace or tighten any connection as necessary The supply gas hose being used must...

Page 6: ...Phase 208 to 240 V supply must be available INSTALLATION Single Phase Three Phase Up to 100 3 6 Up to 100 4 8 Up to 200 3 4 Up to 200 4 6 Up to 300 3 3 Up to 300 4 4 NOTE To power up the heater inside...

Page 7: ...re is adequate 2 Check to make sure all manual valves are open between the fuel source and the burner 3 Check to make sure the proper voltage is supplied to the heater WARNING A qualified electrician...

Page 8: ...ndent upon ambient air conditions Excessive pressure build up could occur in the supply line and lead to line failure Consult your local gas supplier for proper piping and gas codes When storing the h...

Page 9: ...ch gas can pass through the modulator The more voltage that is applied to the magnet the more gas that can pass through The modulator is typically full open when a voltage of about 24 volts DC is appl...

Page 10: ...f any mixing plates are loose or missing fasteners tighten replace as necessary Always use zinc plated or stainless fasteners 3 Observe flame pattern and if necessary take steps to correct obstructed...

Page 11: ...The following is the method for testing major electrical components WARNING A qualified electrician should perform all tests replacements and adjustments Testing the Main Switch Before assuming the C...

Page 12: ...he switch is functioning disconnect and insulate wires leading to the switch N O contacts Connect an ohmmeter or continuity light to the switch N O contacts Place the Heat Fan switch to FAN position T...

Page 13: ...s power to the VFD Burner does not ignite 1 Voltage insufficient 1 Check incoming supply 2 Electrode disconnected adjusted incorrectly defective 2 Connect adjust replace electrode 3 Air Proving Sw Dis...

Page 14: ...ctive 4 Replace Air Proving Sw 5 Flame rod dirty defective 5 Clean Replace Flame Rod 6 Inadequate fuel delivery 6 Fill Tank replace regulators valves check gas lines for obstructions TROUBLESHOOTING D...

Page 15: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 15 WIRING DIAGRAM...

Page 16: ...89 Digital Panel Mounted Voltmeter C70064 3 POSITION SWITCH C70069 FIXING COLLAR C70067 N O CONTACT BLOCK C80025 VFD C80023 R Fan C90025 Power On Indicator Light GREEN C90029 Outlet for Plug C70052 TI...

Page 17: ...C82119 2 X21 2 NIPPLE C82120 2 X90 STREET ELBOW C82121 2 X11 2 REDUCER C82122 11 2 X6 NIPPLE C82123 11 2 X90 ELBOW C82124 11 2 X2 NIPPLE C82125 2 UNION C82126 1 4 X11 2 L NIPPLE C80913 1 4 NPT x 1 4...

Page 18: ...ASSY C82191 PANEL C82192 PANEL C82193 ADAPTER PLATE C82194 R 560 FAN MOUNT ASSY C82195 CORNER STOP C82196 FAN SUPPORT BRACKET C82197 INSULATION BACK PANEL C82087 Serial Number variable data C82088 War...

Page 19: ...P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 19 C82086 E 560 FAN MOUNT ASSY C82105 15 KVA TRANSFORMER C82106 60A CONTACTORS C50242 AUXILIARY CONTACTS C82042 VSR Relay C60205 Use With...