BLAZE 9E MANUAL
OPERATION
REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE USE
OF THE HEATER.
FOLLOW ALL LOCAL CODES
This heater is for use on 240 volts
The cord has a plug as show in the figure
The type of outlet is a 240-volt grounding outlet. When properly installed, it provides a ground connection
through the cord to the heater to protect the operator from electric shock.
Toggle Switch: Turns fan on and off
Adjustable Thermostat Dial with 32F to 150F markings turns heater elements on to reach selected ambient temperature setting and off
once the selected ambient temperature setting is satisfied.
TO START HEATING:
1. Place the heater on a stable and level surface. Make sure that no explosive or combustible fumes or
dust are present
MINIMUM CLEARANCES FROM COMBUSTABLE MATERIALS
OUTLET = 6 feet
SIDES = 1 foot
TOP = 2 feet
REAR = 2 feet
FLOOR = COMBUSTABLE
2. Connect power cord of heater into 240 V / 60 Hz power source. See paragraph “Technical specifications”
in this manual for correct amperage rating
3. Turn the toggle switch into position “on” and the fan starts
4. Set the room thermostat from “heat off” position to a temperature above the ambient room temperature by
turning the knob. Note! The heater will start heating only if the thermostat “calls for heat” meaning that it is
set to higher than prevailing ambient temperature
5. The heater will now operate automatically, controlled by the thermostats
TO STOP HEATING
1. Turn the room thermostat to the “OFF” position
2. Let the fan cool down heater for 2-3 minutes
3. Turn the toggle switch to the “OFF” position
4. Disconnect the power supply plug
NOTE!
THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO
STOP. CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING.