background image

SP10, SP10R, SP20, and SP20R Solar Panels 

 

TABLE 2.  Configurations for Desired Angles 

Hole Locations 

Angle 

Holes P and A Aligned with Holes 1 and Y 

90 

Holes P and A Aligned with Holes 1 and Z 

80 

Holes P and B Aligned with Holes 1 and Y 

70 

Holes P and B Aligned with Holes 1 and Z 

60 

Holes P and C Aligned with Holes 1 and Y 

50 

Holes P and C Aligned with Holes 1 and Z 

40 

Holes P and C Aligned with Holes 2 and Y 

30 

Holes P and C Aligned with Holes 2 and Z 

20 

 

4.  Maintenance

 

An occasional cleaning of the glass improves the solar panel's efficiency. 

If a problem with the solar panel is suspected, the panel may be checked by 
measuring the voltage output.  Check the voltage with a voltmeter connected 
between the two leads of the solar panel.  There must be solar radiation 
incident on the panel and there must be a load connected to the solar panel.  
The load can be the datalogger, other equipment, or a 75 ohm resistor capable 
of dissipating solar panel power between the two leads.  No voltage output 
implies a bad solar panel, regulator, or cable.  The magnitude of the voltage 
output depends on the incident solar radiation. 

5.  Power Considerations 

5.1  Solar Power and Lead Acid Batteries 

The solar panel converts light energy to electricity, or specifically direct 
current.  The direct current produced is used as a charging source for lead acid 
batteries. 

The solar panel operates in both direct and diffuse light (cloudy days), but not 
at night. 

Summary of Contents for SP10

Page 1: ...SP10 SP10R SP20 and SP20R Solar Panels Revision 2 06 C o p y r i g h t 1 9 8 7 2 0 0 6 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...f all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequ...

Page 3: ...allation 2 3 1 Mounting 2 3 2 Orientation 4 4 Maintenance 5 5 Power Considerations 5 5 1 Solar Power and Lead Acid Batteries 5 5 2 Voltage Regulator 6 Appendix A Solar Panel Connector A 1 Figures 1 So...

Page 4: ...This is a blank page...

Page 5: ...s marked SOLAR PANEL located underneath the 700X Control Module An external Gel Cell or AGM lead acid battery can be connected to the CR7 at the terminals marked EXTERNAL BATTERY next to the SOLAR PAN...

Page 6: ...outh if located in the Northern Hemisphere or facing north in the Southern Hemisphere The solar panel mounts to the mast or leg of a tripod or any 1 5 8 schedule 40 pipe see Figure 1 The panel should...

Page 7: ...LEG ALTERNATE POSITION SOLAR PANEL ON MAST 015 PYRANOMETER MOUNTING ARM GILL RADIATION SHIELD DATALOGGER ENCLOSURE FIGURE 1 Solar Panel Mounting RF MODEM RADIO MSX10R DATALOGGER 12 V BATTERY FIGURE 2...

Page 8: ...re given in Table 1 After determining the tilt angle loosen the 5 16 nuts on each side of the solar panel adjust the panel and tighten the two nuts to secure the position See Figure 4 TABLE 1 Solar Pa...

Page 9: ...ked by measuring the voltage output Check the voltage with a voltmeter connected between the two leads of the solar panel There must be solar radiation incident on the panel and there must be a load c...

Page 10: ...ing used by the system The battery must have enough capacity to power the system during times of no charging night or low charging stormy winter days 5 2 Voltage Regulator The solar panel must be regu...

Page 11: ...nd tinned Item 788 connector must be attached to use an SP10 or SP20 with the 21XL With the connector the cable can be inserted directly into the 21XL Charging Port on the side of the Micrologger If i...

Page 12: ...This is a blank page...

Page 13: ...This is a blank page...

Page 14: ...campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientifi...